Compaq ML370 ProLiant ML370 Maintenance and Service Guide - Page 85

699, Diskette Drive Test Error Codes

Page 85 highlights

Diagnostics and Troubleshooting 3-31 600-699, Diskette Drive Test Error Codes The 600 series of diagnostic error codes identifies failures with diskette, diskette drive, or system board functions. Table 3-8 Diskette Drive Test Error Codes Error Code 600-xx 601-xx 602-xx 603-xx 604-xx 605-xx 606-xx 607-xx 608-xx 609-xx 610-xx 699-xx Description Diskette ID drive types test failed. Diskette format failed. Diskette read test failed. Diskette write/read/compute test failed. Diskette random seek test failed. Diskette ID media failed. Diskette speed test failed. Diskette wrap test failed. Diskette write protect test failed. Diskette reset controller test failed. Diskette change line test failed. Diskette drive/media ID error Recommended Action 1. Replace the diskette and retest. 2. Check and/or replace the diskette power and signal cables and retest. 3. Replace the diskette drive and retest. 4. Replace the system board and retest. 1. Replace the media and retest. 2. Run the Configuration Utility and retest. 1100-1199, Serial Test Error Codes The 1100 series of diagnostic error codes identifies failures with serial/parallel interface board or system board functions. Table 3-9 Serial Test Error Codes Error Code 1101-xx 1109-xx Description Serial port test failed. Clock register test failed Recommended Action 1. Check the switch settings on the Serial/Parallel Interface board (if applicable) and retest. 2. Replace the Serial/Parallel Interface board (if applicable) and retest. 3. Replace the system board and retest.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152

Diagnostics and Troubleshooting
3-31
600-699, Diskette Drive Test Error Codes
The 600 series of diagnostic error codes identifies failures with diskette, diskette drive, or
system board functions.
Table 3-8
Diskette Drive Test Error Codes
Error Code
Description
Recommended Action
600-xx
Diskette ID drive types test failed.
601-xx
Diskette format failed.
602-xx
Diskette read test failed.
603-xx
Diskette write/read/compute test
failed.
604-xx
Diskette random seek test failed.
605-xx
Diskette ID media failed.
606-xx
Diskette speed test failed.
607-xx
Diskette wrap test failed.
608-xx
Diskette write protect test failed.
609-xx
Diskette reset controller test
failed.
610-xx
Diskette change line test failed.
1.
Replace the diskette and retest.
2.
Check and/or replace the diskette power and
signal cables and retest.
3.
Replace the diskette drive and retest.
4.
Replace the system board and retest.
699-xx
Diskette drive/media ID error
1.
Replace the media and retest.
2.
Run the Configuration Utility and retest.
1100-1199, Serial Test Error Codes
The 1100 series of diagnostic error codes identifies failures with serial/parallel interface board
or system board functions.
Table 3-9
Serial Test Error Codes
Error Code
Description
Recommended Action
1101-xx
Serial port test failed.
1109-xx
Clock register test failed
1.
Check the switch settings on the Serial/Parallel
Interface board (if applicable) and retest.
2.
Replace the Serial/Parallel Interface board
(if applicable) and retest.
3.
Replace the system board and retest.