Compaq ML370 ProLiant ML370 Maintenance and Service Guide - Page 62

Table 3-2, POST Error Messages, Error Code, Audible Beeps, Probable Source of Problem - beep codes

Page 62 highlights

3-8 Compaq ProLiant ML370 Maintenance and Service Guide Error Code A Critical Error occurred prior to this power-up Unsupported Processor Detected System Halted FATAL ROM ERROR: The System ROM is not properly programmed 101 - ROM Error 101 - I/O ROM Error 102 - System Board Failure 104 - ASR-2 Timer Failure 105 - Current System ROM is corrupt- now booting redundant System ROM 162 - System Options Not Set 163-Time & Date Not Set 164 - Memory Size Error 172 - Configuration Nonvolatile Memory Invalid 173 - Slot ID Mismatch 174 - Configuration/ Slot Mismatch Device Not Found Table 3-2 POST Error Messages Audible Beeps None 1 long, 1 short Probable Source of Problem A catastrophic system error, which caused the server to crash, has been logged. Processor not supported by current system ROM 1 long, 1 short ROM programmed in factory incorrectly Recommended Action Run Diagnostics. Replace failed assembly as indicated. Check documentation for supported processors, and if supported, remove the processor and update the system to latest ROM. Replace the physical ROM part. 1 long, 1 short None None System ROM checksum Options ROM checksum DMA, timers, and so on None System board failure 2L Non-booted ROM image is corrupt Run Diagnostics. Replace failed assembly as indicated. Run Diagnostics. Replace failed assembly as indicated. Replace the system board. Run the Compaq System Configuration Utility. Run Diagnostics. Replace failed assembly as indicated. Flash the ROM utilizing ROMPaq. 2S Configuration incorrect Run the System Configuration Utility and correct. 2S Invalid time or date in configuration memory Run the System Configuration Utility and correct. 2S Configuration memory incorrect Run the System Configuration Utility and correct. None Nonvolatile configuration corrupt Run the System Configuration or jumper installed Utility and correct. None Board replaced, configuration not Run the System Configuration updated Utility and correct. None PCI board not found Run the System Configuration Utility and correct. continued

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152

3-8
Compaq ProLiant ML370 Maintenance and Service Guide
Table 3-2
POST Error Messages
Error Code
Audible Beeps
Probable Source of Problem
Recommended Action
A Critical Error
occurred prior to this
power-up
None
A catastrophic system error,
which caused the server to
crash, has been logged.
Run Diagnostics. Replace failed
assembly as indicated.
Unsupported
Processor Detected
System Halted
1 long, 1 short
Processor not supported by
current system ROM
Check documentation for
supported processors, and if
supported, remove the
processor and update the
system to latest ROM.
FATAL ROM ERROR:
The System ROM is
not properly
programmed
1 long, 1 short
ROM programmed in factory
incorrectly
Replace the physical ROM part.
101 - ROM Error
1 long, 1 short
System ROM checksum
Run Diagnostics. Replace failed
assembly as indicated.
101 - I/O ROM Error
None
Options ROM checksum
Run Diagnostics. Replace failed
assembly as indicated.
102 - System Board
Failure
None
DMA, timers, and so on
Replace the system board. Run
the Compaq System
Configuration Utility.
104 - ASR-2 Timer
Failure
None
System board failure
Run Diagnostics. Replace failed
assembly as indicated.
105 - Current System
ROM is corrupt—
now booting
redundant System
ROM
2L
Non-booted ROM image is
corrupt
Flash the ROM utilizing
ROMPaq.
162 - System
Options Not Set
2S
Configuration incorrect
Run the System Configuration
Utility and correct.
163—Time & Date
Not Set
2S
Invalid time or date in
configuration memory
Run the System Configuration
Utility and correct.
164 - Memory Size
Error
2S
Configuration memory incorrect
Run the System Configuration
Utility and correct.
172 - Configuration
Nonvolatile Memory
Invalid
None
Nonvolatile configuration corrupt
or jumper installed
Run the System Configuration
Utility and correct.
173 - Slot ID
Mismatch
None
Board replaced, configuration not
updated
Run the System Configuration
Utility and correct.
174 - Configuration/
Slot Mismatch Device
Not Found
None
PCI board not found
Run the System Configuration
Utility and correct.
continued