Dell PowerConnect Brocade M6505 Hardware Reference Manual - Page 58
Environmental specifications, Electrical specifications, Architectural specifications, Table 10
View all Dell PowerConnect Brocade M6505 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 58 highlights
A Environmental specifications Environmental specifications Table 10 lists the environmental specifications for the SAN I/O Module. TABLE 10 Condition Environmental specifications Operating Non-operating Temperature Humidity Altitude Shock Vibration Air flow 0°C to 40°C (32°F to 104°F) 10% to 90%, non-condensing at 29°C (84.2°F) Up to 3,048 m (10,000 ft) 20 G for 6 ms 0.4 G at 5-500 Hz for 60 minutes 30°C (86 °F) Ambient: Approx. 3CFM 40°C (104°F) Ambient: Approx. 9CFM -20°C to 70°C (-4°F to 158°F) 5% to 95%, non-condensing at 38°C (100.4 °F) 10,668 m (35,000 ft) 50 G with velocity change of 4216 mm/sec squared 0.5 G at 2-200 Hz for 15 minutes None required Electrical specifications Table 11 lists the electrical specifications for the SAN I/O Module. TABLE 11 Feature Electrical specifications Description DC input Power consumption 12V and 3.3V from chassis 30W (idle) to 40W (maximum) Architectural specifications The SAN I/O Module meets the specifications shown in Table 12. TABLE 12 Feature Architectural specifications Description Scalability Certified maximum Refer to the current Brocade Scalability Guidelines publication. Refer to the current Brocade Scalability Guidelines publication. Performance 4.25/8.50/14.025 Gbps line speed, full duplex Fabric latency (Native Fabric mode only)