Dell PowerConnect Brocade M6505 Hardware Reference Manual - Page 58

Environmental specifications, Electrical specifications, Architectural specifications, Table 10

Page 58 highlights

A Environmental specifications Environmental specifications Table 10 lists the environmental specifications for the SAN I/O Module. TABLE 10 Condition Environmental specifications Operating Non-operating Temperature Humidity Altitude Shock Vibration Air flow 0°C to 40°C (32°F to 104°F) 10% to 90%, non-condensing at  29°C (84.2°F) Up to 3,048 m (10,000 ft) 20 G for 6 ms 0.4 G at 5-500 Hz for 60 minutes 30°C (86 °F) Ambient: Approx. 3CFM 40°C (104°F) Ambient: Approx. 9CFM -20°C to 70°C (-4°F to 158°F) 5% to 95%, non-condensing at  38°C (100.4 °F) 10,668 m (35,000 ft) 50 G with velocity change of 4216 mm/sec squared 0.5 G at 2-200 Hz for 15 minutes None required Electrical specifications Table 11 lists the electrical specifications for the SAN I/O Module. TABLE 11 Feature Electrical specifications Description DC input Power consumption 12V and 3.3V from chassis 30W (idle) to 40W (maximum) Architectural specifications The SAN I/O Module meets the specifications shown in Table 12. TABLE 12 Feature Architectural specifications Description Scalability Certified maximum Refer to the current Brocade Scalability Guidelines publication. Refer to the current Brocade Scalability Guidelines publication. Performance 4.25/8.50/14.025 Gbps line speed, full duplex Fabric latency (Native Fabric mode only)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

46
Brocade M6505 16 Gbps Fibre Channel SAN I/O Module Hardware Reference Manual
53-1002576-02
Environmental specifications
A
Environmental specifications
Table 10
lists the environmental specifications for the SAN I/O Module.
Electrical specifications
Table 11
lists the electrical specifications for the SAN I/O Module.
Architectural specifications
The SAN I/O Module meets the specifications shown in
Table 12
.
TABLE 10
Environmental specifications
Condition
Operating
Non-operating
Temperature
0°C to 40°C (32°F to 104°F)
-20°C to 70°C (-4°F to 158°F)
Humidity
10% to 90%, non-condensing at
29°C (84.2°F)
5% to 95%, non-condensing at
38°C (100.4 °F)
Altitude
Up to 3,048 m (10,000 ft)
10,668 m (35,000 ft)
Shock
20 G for 6 ms
50 G with velocity change of 4216
mm/sec squared
Vibration
0.4 G at 5–500 Hz for 60 minutes
0.5 G at 2–200 Hz for 15 minutes
Air flow
30°C (86 °F) Ambient: Approx. 3CFM
40°C (104°F) Ambient: Approx. 9CFM
None required
TABLE 11
Electrical specifications
Feature
Description
DC input
12V and 3.3V from chassis
Power consumption
30W (idle) to 40W (maximum)
TABLE 12
Architectural specifications
Feature
Description
Scalability
Refer to the current
Brocade Scalability Guidelines
publication.
Certified maximum
Refer to the current
Brocade Scalability Guidelines
publication.
Performance
4.25/8.50/14.025 Gbps line speed, full duplex
Fabric latency
(Native Fabric mode only)
<1.2 μsec with no contention
Maximum frame size
2112-byte payload
Class of service
Class 2
Class 3
Class F (interswitch frames)