Dell PowerEdge R440 EMC Installation and Service Manual - Page 106

M.2 SSD module, Installing the M.2 SSD module

Page 106 highlights

Figure 74. Installing PERC card into internal PERC riser Next steps 1. Install the internal PERC riser. 2. Install the air shroud. 3. Follow the procedure listed in After working inside your system on page 59. M.2 SSD module NOTE: The write-protect switch is on the IDSDM or vFlash module. Installing the M.2 SSD module Prerequisites 1. Follow the safety guidelines listed in Safety instructions on page 58 2. Remove the air shroud. 3. Remove the BOSS card. NOTE: The procedure to remove the BOSS card is similar to the removing an expansion card. Steps 1. Connect the M.2 SSD module to the connector on the BOSS card. 2. Place the retention strap on the M.2 SSD module, and tighten the screw to secure the module. 106 Installing and removing system components

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145

Figure 74. Installing PERC card into internal PERC riser
Next steps
1.
Install the internal PERC riser.
2.
Install the air shroud.
3.
Follow the procedure listed in
After working inside your system
on page 59.
M.2 SSD module
NOTE:
The write-protect switch is on the IDSDM or vFlash module.
Installing the M.2 SSD module
Prerequisites
1.
Follow the safety guidelines listed in
Safety instructions
on page 58
2.
Remove the air shroud
.
3.
Remove the BOSS card.
NOTE:
The procedure to remove the BOSS card is similar to the
removing an expansion card
.
Steps
1.
Connect the M.2 SSD module to the connector on the BOSS card.
2.
Place the retention strap on the M.2 SSD module, and tighten the screw to secure the module.
106