Dell PowerEdge R440 EMC Installation and Service Manual - Page 29
Standard operating temperature, Expanded operating temperature restrictions
![]() |
View all Dell PowerEdge R440 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
Table 29. Operating temperature derating specifications Operating temperature derating Specifications Up to 35°C (95°F) Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft). 35°C to 40°C (95°F to 104°F) Maximum temperature is reduced by 1°C/175 m (1°F/319 ft) above 950 m (3,117 ft). 40°C to 45°C (104°F to 113°F) Maximum temperature is reduced by 1°C/125 m (1°F/228 ft) above 950 m (3,117 ft). Standard operating temperature Table 30. Standard operating temperature specifications Standard operating temperature Specifications Continuous operation (for altitude less than 950 m or 3117 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment. ft) Expanded operating temperature Table 31. Expanded operating temperature specifications Expanded operating temperature Specifications Continuous operation 5°C to 40°C at 5% to 85% RH with 29°C dew point. NOTE: Outside the standard operating temperature (10°C to 40°C), the system can operate continuously in temperatures as low as 5°C and as high as 40°C. For temperatures between 35°C and 40°C, de-rate maximum allowable temperature by 1°C per 175 m above 950 m (1°F per 319 ft). ≤ 1% of annual operating hours -5°C to 45°C at 5% to 90% RH with 29°C dew point. NOTE: Outside the standard operating temperature (10°C to 40°C), the system can operate down to -5°C or up to 45°C for a maximum of 1% of its annual operating hours. For temperatures between 40°C and 45°C, de-rate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft). NOTE: When operating in the expanded temperature range, system performance may be impacted. NOTE: When operating in the expanded temperature range, ambient temperature warnings may be reported on the bezel's LCD panel and in the System Event Log. Expanded operating temperature restrictions • Do not perform a cold startup below 5°C. • The operating temperature specified is for a maximum altitude of 3048 m (10,000 ft). • 105 W/4C, 115 W/6C, 130 W/8C, 140 W/14C or higher wattage processor (TDP>140 W) are not supported. • Redundant power supply configuration is required. • Non-Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported. • NVMe drives are not supported. • Apache Pass DIMM and NVDIMM are not supported. Technical specifications 29
![](/manual_guide/products/dell-poweredge-r440-emc-installation-service-manual-3131fb9/29.png)