Dell PowerEdge R440 EMC Installation and Service Manual - Page 127
Installing a non-redundant cabled AC power supply unit
View all Dell PowerEdge R440 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 127 highlights
Figure 101. Removing non-redundant cabled AC PSU Next steps 1. Install a non-redundant cabled AC power supply. Installing a non-redundant cabled AC power supply unit Prerequisites 1. Follow the safety guidelines listed in Safety instructions. Steps 1. Unpack the new power supply unit (PSU). 2. Slide the new PSU into the PSU cage until the PSU is fully seated. 3. Using a Phillips #2 screwdriver, replace the screw to secure the PSU to the system. Figure 102. Installing a non-redundant cabled AC PSU Next steps 1. Connect the PSU cables to the connectors on the system board. 2. If applicable, install the expansion card riser. 3. Install the air shroud. 4. Follow the procedure listed in After working inside your system on page 59. Installing and removing system components 127