Thermtrip, Presence, E141C, CPU Mismatch, Utility. See
View all Dell PowerVault DL2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
Table 1-6. LCD Status Messages (continued) Code Text Causes Corrective Actions E1414 CPU # Thermtrip Specified microprocessor See "Troubleshooting is out of acceptable System Cooling Problems" temperature range and has on page 140. If the problem halted operation. persists, ensure that the microprocessor heat sinks are properly installed. See "Troubleshooting the Microprocessors" on page 150. NOTE: The LCD continues to display this message until the system's power cord is disconnected and reconnected to the AC power source, or the SEL is cleared using either Server Assistant or the BMC Management Utility. See the Dell OpenManage Baseboard Management Controller User's Guide for information about these utilities. E1418 CPU # Presence Specified processor is missing or bad, and the system is in an unsupported configuration. See "Troubleshooting the Microprocessors" on page 150. E141C CPU Mismatch Processors are in a Ensure that your configuration unsupported processors match and by Dell. conform to the type described in the Microprocessor Technical Specifications outlined in your system's Getting Started Guide. About Your System 23