Dell PowerVault DL2000 DL2000 Hardware Owner's Manual - Page 30
SBE Log, Disable Crd, Mem Spare Crd, Mem Mirror, Fatal NB Mem
View all Dell PowerVault DL2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
Table 1-6. LCD Status Messages (continued) Code Text Causes Corrective Actions E2111 SBE Log Disable Crd # DIMM ## The system BIOS has See "Troubleshooting disabled memory single-bit System Memory" on error (SBE) logging, and page 142. will not resume logging further SBEs until the system is rebooted. "##" represents the DIMM implicated by the BIOS. If no memory riser card is present, the "Crd #" string is left out of the message. E2112 Mem Spare Crd # DIMM ## The system BIOS has See "Troubleshooting spared the memory System Memory" on because it has determined page 142. that the memory had too many errors. "## & ##" represents the DIMM pair implicated by the BIOS. If no memory card is present, the "Crd #" string is left out of the message. E2113 Mem Mirror Crd # DIMM ## & ## The system BIOS has See "Troubleshooting disabled memory System Memory" on mirroring because it has page 142. determined that one half of the mirror has had too many errors. "## & ##" represents the DIMM pair implicated by the BIOS. If no memory card is present, the "Crd #" string is left out of the message. E2118 Fatal NB Mem CRC One of the connections in See "Troubleshooting the Fully Buffered DIMM System Memory" on (FBD) memory subsystem page 142. link on the Northbound side has failed. 30 About Your System