Table 1-7., System Messages, Message, Causes, Corrective Actions, Caution! NVRAM_CLR
View all Dell PowerVault DL2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
Table 1-7. System Messages Message Causes Corrective Actions Alert! Redundant memory disabled! Memory configuration does not support redundant memory. Installed memory modules Ensure that all memory are not the same type and modules are of the same size; faulty memory type and size and that they module(s). are properly installed. If the problem persists, see "Troubleshooting System Memory" on page 142. Attempting to update Remote Configuration. Please wait... Remote Configuration Wait until the process is request has been detected complete. and is being processed. BIOS Update Attempt Failed! Remote BIOS update attempt failed. Retry the BIOS update. If problem persists, see "Getting Help" on page 167. Caution! NVRAM_CLR jumper is installed on system board. NVRAM_CLR jumper is Remove NVRAM_CLR installed. CMOS has been jumper. See Figure 6-1 for cleared. jumper location. CPUs with different cache sizes detected! Microprocessors with different cache sizes are installed. Ensure that all microprocessors have the same cache size and that they are properly installed. See "Processors" on page 105. Decreasing available memory Faulty or improperly See "Troubleshooting installed memory modules. System Memory" on page 142. About Your System 33