Table 1-7., System Messages, Message, Causes, Corrective Actions, Caution! NVRAM_CLR

Page 33 highlights

Table 1-7. System Messages Message Causes Corrective Actions Alert! Redundant memory disabled! Memory configuration does not support redundant memory. Installed memory modules Ensure that all memory are not the same type and modules are of the same size; faulty memory type and size and that they module(s). are properly installed. If the problem persists, see "Troubleshooting System Memory" on page 142. Attempting to update Remote Configuration. Please wait... Remote Configuration Wait until the process is request has been detected complete. and is being processed. BIOS Update Attempt Failed! Remote BIOS update attempt failed. Retry the BIOS update. If problem persists, see "Getting Help" on page 167. Caution! NVRAM_CLR jumper is installed on system board. NVRAM_CLR jumper is Remove NVRAM_CLR installed. CMOS has been jumper. See Figure 6-1 for cleared. jumper location. CPUs with different cache sizes detected! Microprocessors with different cache sizes are installed. Ensure that all microprocessors have the same cache size and that they are properly installed. See "Processors" on page 105. Decreasing available memory Faulty or improperly See "Troubleshooting installed memory modules. System Memory" on page 142. About Your System 33

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188

About Your System
33
Table 1-7.
System Messages
Message
Causes
Corrective Actions
Alert! Redundant
memory disabled!
Memory
configuration does
not support
redundant memory.
Installed memory modules
are not the same type and
size; faulty memory
module(s).
Ensure that all memory
modules are of the same
type and size and that they
are properly installed. If the
problem persists, see
"Troubleshooting System
Memory" on page 142.
Attempting to
update Remote
Configuration.
Please wait...
Remote Configuration
request has been detected
and is being processed.
Wait until the process is
complete.
BIOS Update
Attempt Failed!
Remote BIOS update
attempt failed.
Retry the BIOS update. If
problem persists, see
"Getting Help" on page 167.
Caution! NVRAM_CLR
jumper is
installed on
system board.
NVRAM_CLR jumper is
installed. CMOS has been
cleared.
Remove NVRAM_CLR
jumper. See Figure 6-1 for
jumper location.
CPUs with
different cache
sizes detected!
Microprocessors with
different cache sizes are
installed.
Ensure that all
microprocessors have the
same cache size and that
they are properly installed.
See "Processors" on
page 105.
Decreasing
available memory
Faulty or improperly
installed memory modules.
See "Troubleshooting
System Memory" on
page 142.