Dell PowerVault DL2000 DL2000 Hardware Owner's Manual - Page 29
E201E, POST Mem Test, E201F, DRAC Config, CPU Config, E2021 Memory, Population, POST Fail, MBE Crd
View all Dell PowerVault DL2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
Table 1-6. LCD Status Messages (continued) Code Text Causes Corrective Actions E201E POST Mem Test BIOS POST memory test failure. See "Troubleshooting System Memory" on page 142. If problem persists, see "Getting Help" on page 167. E201F DRAC Config Dell remote access controller (DRAC) configuration failure. Check screen for specific error messages. Ensure that DRAC cables and connectors are properly seated. If problem persists, see your DRAC documentation. E2020 CPU Config CPU configuration failure. Check screen for specific error messages. E2021 Memory Population Incorrect memory Check screen for specific configuration. Memory error messages. See population order incorrect. "Troubleshooting System Memory" on page 142. E2022 POST Fail General failure after video. Check screen for specific error messages. E2110 MBE Crd # DIMM ## & ## One of the DIMMs in the See "Troubleshooting set implicated by "## & System Memory" on ##" has had a memory page 142. multi-bit error (MBE). If no memory card is present, the "Crd #" string is left out of the message. About Your System 29