Removing the Optical Drive Cable, optical drive.

Page 99 highlights

Removing the Optical Drive Cable CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product. 1 Turn off the system, including any attached peripherals, and disconnect the system from its electrical outlet. 2 Remove the bezel. See "Removing the Front Bezel" on page 65. 3 Open the system. See "Opening the System" on page 67. 4 Release the CD-to-side plane cable from the side plane by pressing outward on the optical drive data cable ejectors until they reach the locked position. 5 Remove the cable from the cable guides on the cooling shroud. 6 Remove the CD-to-side plane cable from the back of the optical drive. See Figure 3-17. Installing the Optical Drive Cable 1 Connect the CD-to-side plane cable (labeled CD) to the back of the optical drive. 2 Route the cable on the side of the cooling shroud and then through the cable guides on the cooling shroud. 3 With the optical drive data cable ejectors in the open position on the side plane, insert the cable (labeled sideplane) into the connector until the ejectors lock. 4 Close the system. See "Closing the System" on page 67. 5 Reconnect the system and peripherals to their power sources, and turn them on. Installing System Components 99

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188

Installing System Components
99
Removing the Optical Drive Cable
CAUTION:
Many repairs may only be done by a certified service technician. You
should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not covered
by your warranty. Read and follow the safety instructions that came with the
product.
1
Turn off the system, including any attached peripherals, and disconnect
the system from its electrical outlet.
2
Remove the bezel. See "Removing the Front Bezel" on page 65.
3
Open the system. See "Opening the System" on page 67.
4
Release the CD-to-side plane cable from the side plane by pressing
outward on the optical drive data cable ejectors until they reach the locked
position.
5
Remove the cable from the cable guides on the cooling shroud.
6
Remove the CD-to-side plane cable from the back of the optical drive. See
Figure 3-17.
Installing the Optical Drive Cable
1
Connect the CD-to-side plane cable (labeled CD) to the back of the
optical drive.
2
Route the cable on the side of the cooling shroud and then through the
cable guides on the cooling shroud.
3
With the optical drive data cable ejectors in the open position on the side
plane, insert the cable (labeled sideplane) into the connector until the
ejectors lock.
4
Close the system. See "Closing the System" on page 67.
5
Reconnect the system and peripherals to their power sources, and turn
them on.