Dell PowerVault DR6000 Owners Manual - Page 111
Error Code, Message Information, CPU0704, Message, Details, Action, FAN0000, HWC1001, Getting Help
![]() |
View all Dell PowerVault DR6000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 111 highlights
Error Code CPU0704 FAN0000 FAN0001 FAN1201 HWC1001 HWC2003 Message Information 5. If the issue persists, see Getting Help. Message Details Action CPU machine check error detected. System event log and operating system logs may indicate that the exception is external to the processor. 1. Check system and operating system logs for exceptions. If no exceptions are found, continue. 2. Turn off the system and remove input power for one minute. 3. Ensure the processor is seated correctly. 4. Reapply input power and turn on the system. 5. If the issue persists, see Getting Help. Message Details Action Message Details Action Message Details Action Message Details Action Message Details Fan RPM is less than the lower warning threshold. Fan operating speed is out of range. Remove and reinstall the fan. If the issue persists, see Getting Help. Fan RPM is less than the lower critical threshold. Fan operating speed is out of range. Remove and reinstall the fan. If the issue persists, see Getting Help. Fan redundancy is lost. Fan has failed. Remove and reinstall failed fans or install additional fans. The is absent. The absent device may be necessary for proper operation. System functionality may be degraded. Reinstall or reconnect the hardware. The storage cable is not connected, or is improperly connected. The cable may be necessary for proper operation. System functionality may be degraded. 111
![](/manual_guide/products/dell-powervault-dr6000-owners-manual-ab3571d/111.png)