Dell PowerVault DR6000 Owners Manual - Page 119
Error Code, Message Information, RFM2001, Message, Details, Action, SEC0031, SEL0006
View all Dell PowerVault DR6000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 119 highlights
Error Code RFM2001 RFM2002 RFM2004 RFM2006 SEC0031 SEC0033 SEL0006 Message Information Message Details Action Internal Dual SD Module is absent. The SD card module is not detected or not installed. If unintended, reinstall the SD module. Message Details Action Internal Dual SD Module is offline. The SD card module is installed but may be improperly installed or configured incorrectly. Reinstall the SD module. Message Details Action Failure detected on Internal Dual SD Module . The SD card module is installed but improperly configured or failed to initialize. Reinstall the SD module and remove and reinstall SD cards. Message Details Action Internal Dual SD Module is write protected. The module is write-protected. Changes may not be written to the media. If unintended, remove the media and disable write protection. Message Details Action The chassis is open while the power is on. The chassis is open. System performance may be degraded, and security may be compromised. Close the chassis. Check system logs. Message Details Action The chassis is open while the power is off. The chassis was opened while the power was off. System security may have been compromised. Close the chassis and verify hardware inventory. Check system logs. Message Details Action All event logging is disabled. This message is displayed when all event logging has been disabled by the user. If unintended, re-enable logging. 119