Dell PowerVault DR6000 Owners Manual - Page 116

Error Code, Message Information, Action, PSU0016, Message, Details, PSU0031, PSU0032, PSU0033,

Page 116 highlights

Error Code PSU0016 PSU0031 PSU0032 PSU0033 PSU0034 116 Message Information Action Install matched power supplies and review proper configuration in this manual. Message Details Action Power supply is absent. The power supply has been removed or has failed. 1. Remove and reinstall the power supply. 2. Check cables and subsystem components in the system for damage. 3. If the issue persists, see Getting Help. Message Details Action Message Details Action Message Details Action Message Details Action Cannot communicate with power supply . The power supply may operate, however power supply monitoring is degraded. System performance may be degraded. Remove and reinstall the power supply. If the issue persists, see Getting Help. The temperature for power supply is in a warning range. System performance may be degraded. Check the system operating environment, including airflow and inlet temperature. Check system logs for temperature and thermal component failures. The temperature for power supply is outside of the allowable range. System performance may be degraded. Check the system operating environment, including airflow and inlet temperature. Check system logs for temperature and thermal component failures. An under voltage fault detected on power supply . This failure may be the result of an electrical issue with cables or subsystem components in the system. 1. Remove and reinstall the power supply. 2. Check cables and subsystem components in the system for damage.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

Error Code
Message Information
Action
Install matched power supplies and review proper
configuration in this manual.
PSU0016
Message
Power supply <
number
> is absent.
Details
The power supply has been removed or has failed.
Action
1.
Remove and reinstall the power supply.
2.
Check cables and subsystem components in the system
for damage.
3.
If the issue persists, see
Getting Help
.
PSU0031
Message
Cannot communicate with power supply <
number
>.
Details
The power supply may operate, however power supply
monitoring is degraded. System performance may be
degraded.
Action
Remove and reinstall the power supply. If the issue persists,
see
Getting Help
.
PSU0032
Message
The temperature for power supply <
number
> is in a warning
range.
Details
System performance may be degraded.
Action
Check the system operating environment, including airflow
and inlet temperature. Check system logs for temperature
and thermal component failures.
PSU0033
Message
The temperature for power supply <
number
> is outside of
the allowable range.
Details
System performance may be degraded.
Action
Check the system operating environment, including airflow
and inlet temperature. Check system logs for temperature
and thermal component failures.
PSU0034
Message
An under voltage fault detected on power supply <
number
>.
Details
This failure may be the result of an electrical issue with
cables or subsystem components in the system.
Action
1.
Remove and reinstall the power supply.
2.
Check cables and subsystem components in the system
for damage.
116