Fluke 1586A/2DS Product Manual - Page 28

DC Voltage, DC Current

Page 28 highlights

1586A Users Manual DC Voltage Maximum Input 50 V on any range Common Mode Rejection 140 dB at 50 Hz or 60 Hz (1 kΩ unbalance in LOW lead) ±50 V peak maximum Normal Mode Rejection 55 dB for power line frequency ±0.1 %, ±120 % of range peak maximum A/D Linearity 2 ppm of measurement + 1 ppm of range Input Bias Current 30 pA at 25 °C DC Voltage Accuracy Accuracy is given as ± (% measurement + % of range). Basic accuracy specification is for Channel 1, medium or slow sample rate. For channels x01 through x20 or when using Fast sample rate, add the numbers given in the table to the accuracy specification. If the environment temperature is outside the specified range, multiply the temperature coefficient numbers by the temperature deviation and add to the accuracy specification. Range ±100 mV ±1 V ±10 V ±50 V Accuracy Channel 1 0.0037 % + 0.0035 % 0.0025 % + 0.0007 % 0.0024 % + 0.0005 % 0.0038 % + 0.0012 % Ch. x01 - x20 add 2 μV add 2 μV − − Fast Sample Rate add 0.0008 % of range add 0.0008 % of range add 0.0008 % of range add 0.0008 % of range T.C./ °C Outside 18 °C to 28 °C 0.0005 % + 0.0005 % 0.0005 % + 0.0001 % 0.0005 % + 0.0001 % 0.0005 % + 0.0001 % DC Voltage Input Characteristics Range ±100 mV Resolution Slow / Medium 0.1 μV Fast 1 μV ±1 V 1 μV 10 μV ±10 V 10 μV 100 μV ±50 V 100 μV 1 mV [1] - Input beyond ±12 V is clamped. The clamp current is up to 3 mA. Input Impedance 10 GΩ [1] 10 GΩ [1] 10 GΩ [1] 10 MΩ ±1 % DC Current Input Protection 0.15 A resettable PTC DC Current Accuracy Accuracy is given as ± (% measurement + % of range). Basic accuracy specification is for medium or slow sample rate. When using a fast sample rate, add the number given in the table to the accuracy specification. If the environment temperature is outside the specified range, multiply the temperature coefficient numbers by the temperature deviation and add to the accuracy specification. Range ±100 μA ±1 mA ±10 mA ±100 mA Accuracy 0.015 % + 0.0035 % 0.015 % + 0.0011 % 0.015 % + 0.0035 % 0.015 % + 0.0035 % Fast Sample Rate add 0.0008 % of range add 0.0008 % of range add 0.0008 % of range add 0.0008 % of range T.C./ °C Outside 18 °C to 28 °C 0.002 % + 0.001 % 0.002 % + 0.001 % 0.002 % + 0.001 % 0.002 % + 0.001 % 1-20 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135

1586A
Users Manual
1-20
DC Voltage
Maximum Input
......................................................
50 V on any range
Common Mode Rejection
.....................................
140 dB at 50 Hz or 60 Hz (1 k
Ω
unbalance in LOW lead) ±50 V peak
maximum
Normal Mode Rejection
........................................
55 dB for power line frequency ±0.1 %, ±120 % of range peak
maximum
A/D Linearity
..........................................................
2 ppm of measurement + 1 ppm of range
Input Bias Current
.................................................
30 pA at 25 °C
DC Voltage Accuracy
Accuracy is given as ± (% measurement + % of range). Basic accuracy specification is for Channel 1, medium or slow
sample rate. For channels x01 through x20 or when using Fast sample rate, add the numbers given in the table to the
accuracy specification. If the environment temperature is outside the specified range, multiply the temperature coefficient
numbers by the temperature deviation and add to the accuracy specification.
Range
Accuracy
Channel 1
Ch. x01 – x20
Fast
Sample Rate
T.C./ °C Outside
18 °C to 28 °C
±100 mV
0.0037 % + 0.0035 %
add 2
μ
V
add 0.0008 % of range
0.0005 % + 0.0005 %
±1 V
0.0025 % + 0.0007 %
add 2
μ
V
add 0.0008 % of range
0.0005 % + 0.0001 %
±10 V
0.0024 % + 0.0005 %
add 0.0008 % of range
0.0005 % + 0.0001 %
±50 V
0.0038 % + 0.0012 %
add 0.0008 % of range
0.0005 % + 0.0001 %
DC Voltage Input Characteristics
Range
Resolution
Input Impedance
Slow / Medium
Fast
±100 mV
0.1
μ
V
1
μ
V
10 G
Ω
[1]
±1 V
1
μ
V
10
μ
V
10 G
Ω
[1]
±10 V
10
μ
V
100
μ
V
10 G
Ω
[1]
±50 V
100
μ
V
1 mV
10 M
Ω
±1 %
[1] - Input beyond ±12 V is clamped. The clamp current is up to 3 mA.
DC Current
Input Protection
....................................................
0.15 A resettable PTC
DC Current Accuracy
Accuracy is given as ± (% measurement + % of range). Basic accuracy specification is for medium or slow sample rate.
When using a fast sample rate, add the number given in the table to the accuracy specification. If the environment
temperature is outside the specified range, multiply the temperature coefficient numbers by the temperature deviation and
add to the accuracy specification.
Range
Accuracy
Fast Sample Rate
T.C./ °C Outside
18 °C to 28 °C
±100
μ
A
0.015 % + 0.0035 %
add 0.0008 % of range
0.002 % + 0.001 %
±1 mA
0.015 % + 0.0011 %
add 0.0008 % of range
0.002 % + 0.001 %
±10 mA
0.015 % + 0.0035 %
add 0.0008 % of range
0.002 % + 0.001 %
±100 mA
0.015 % + 0.0035 %
add 0.0008 % of range
0.002 % + 0.001 %
Shop for Fluke products online at:
1.888.610.7664
www.
MyFlukeStore
.com