Fluke 726 FE 726 Users Manual - Page 22

Table 4. Key Functions cont., Description, Toggles between voltage, mA sourcing - calibration manual

Page 22 highlights

726 Users Manual Table 4. Key Functions (cont.) No Name Description Cycles through : E Slow repeating 0 % - 100 % - 0 % ramp L TRIGGER/STOP L P Fast repeating 0 % - 100 % - 0 % ramp N Repeating 0 % - 100 % - 0 % ramp in 25 % steps Used for the pulse train and totalizer functions. M XW Y Z Return to Recall Increases or decreases the source level. Cycles through the 2-, 3-, and 4-wire selections. Moves through the memory locations of Calibrator setups. Moves through the configuration menus. N S ENTER Saves and recalls setups & data. ENTER is used in the configuration menus. O C Used to enter and navigate the configuration menus. P M Cycles the Calibrator through MEASURE and SOURCE modes in the lower display. Q T Selects TC (thermocouple) measurement and sourcing function in the lower display. Repeated pushes cycle through the thermocouple types. R HART V Toggles between voltage, mA sourcing, or mA simulate functions in the lower display. Inserts a 250 Ω resistor when in mA. S R Selects RTD (resistance temperature detector) measurement and sourcing function in lower display. Repeated pushes cycle through the RTD types. Selects resistance mode. T U Selects the pressure measurement and sourcing function. Repeated pushes cycle through the different pressure units. 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

726
Users Manual
12
Table 4. Key Functions (cont.)
No
Name
Description
L
TRIGGER/STOP
L
Cycles through :
E
Slow repeating 0 % - 100 % - 0 % ramp
P
Fast repeating 0 % - 100 % - 0 % ramp
N
Repeating 0 % - 100 % - 0 % ramp in 25 % steps
Used for the pulse train and totalizer functions.
M
XW
Y
Z
Return to
Recall
Increases or decreases the source level.
Cycles through the 2-, 3-, and 4-wire selections.
Moves through the memory locations of Calibrator setups.
Moves through the configuration menus.
N
S
ENTER
Saves and recalls setups & data.
ENTER is used in the configuration menus.
O
C
Used to enter and navigate the configuration menus.
P
M
Cycles the Calibrator through MEASURE and SOURCE modes in the lower display.
Q
T
Selects TC (thermocouple) measurement and sourcing function in the lower display. Repeated
pushes cycle through the thermocouple types.
R
HART
V
Toggles between voltage, mA sourcing, or mA simulate functions in the lower display.
Inserts a 250
resistor when in mA.
S
R
Selects RTD (resistance temperature detector) measurement and sourcing function in lower
display. Repeated pushes cycle through the RTD types. Selects resistance mode.
T
U
Selects the pressure measurement and sourcing function. Repeated pushes cycle through the
different pressure units.