HP 11kVA 400 Volt IEC309 16A 3-Phase Input 30xC13/3xC19 HP Monitored Power Dis - Page 110

Type 2 or 3 (PDU or User), Table 11. System Alarms and Events Continued

Page 110 highlights

Maintenance and Alarms Table 11. System Alarms and Events (Continued) Type Code Identification Code Alarm or Event 1 02824 Device CAN Id out of range 1 02825 1 02826 1 02827 1 01281 1 01282 1 01283 1 01284 1 01285 1 01286 Time duration of a command is too long Report acquired from CAN device is wrong Report descriptor acquired from CAN device is wrong Mutex not available HID object Id out of range Report empty or not valid Report Id out of range Not enough memory in HEAP Duration of the acquisition of Teridian is too long 1 01282 1 02561 1 02562 1 02563 1 02564 1 02565 1 02566 1 02567 1 01025 1 01026 HID object Id not in list of data saved in EEPROM *Not used *Not used *Not used Wrong data type String too long *Not used *Not used *Not used Semantic error 1 01027 1 01028 1 01029 1 01030 1 01031 1 01032 1 01033 1 03585 1 03586 1 03587 Impossible to open log file Impossible to write data in log file Impossible to seek data in log file Impossible to read data in log file Mutex not available *Not used Impossible to clear LOG file Initialization of SSH task failed Reading of the host key file (or table) failed Listening of SSH socket failed 1 03588 1 03589 1 03590 1 03591 1 03592 Acceptance of SSH socket failed Break received Max number of SSH connection reached Certificate error *Not used Type 2 or 3 (PDU or User) Type 2 alarms and events are triggered from the PDU. These alarms and events are primarily threshold crossings when the operation measurement is beyond the threshold value range setting. Type 2 alarms and events also provide the state of optional connected equipment. Type 3 alarms and events are triggered from user actions. HP Monitored PDU User's Guide P-164000281-Rev 1 104

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120

Maintenance and Alarms
HP Monitored PDU User’s Guide
P-164000281—Rev 1
104
Type 2 or 3 (PDU or User)
Type 2 alarms and events are triggered from the PDU. These alarms and events are primarily threshold
crossings when the operation measurement is beyond the threshold value range setting. Type 2 alarms and
events also provide the state of optional connected equipment.
Type 3 alarms and events are triggered from user actions.
1
02824
Device CAN Id out of range
1
02825
Time duration of a command is too long
1
02826
Report acquired from CAN device is wrong
1
02827
Report descriptor acquired from CAN device is wrong
1
01281
Mutex not available
1
01282
HID object Id out of range
1
01283
Report empty or not valid
1
01284
Report Id out of range
1
01285
Not enough memory in HEAP
1
01286
Duration of the acquisition of Teridian is too long
1
01282
HID object Id not in list of data saved in EEPROM
1
02561
*Not used
1
02562
*Not used
1
02563
*Not used
1
02564
Wrong data type
1
02565
String too long
1
02566
*Not used
1
02567
*Not used
1
01025
*Not used
1
01026
Semantic error
1
01027
Impossible to open log file
1
01028
Impossible to write data in log file
1
01029
Impossible to seek data in log file
1
01030
Impossible to read data in log file
1
01031
Mutex not available
1
01032
*Not used
1
01033
Impossible to clear LOG file
1
03585
Initialization of SSH task failed
1
03586
Reading of the host key file (or table) failed
1
03587
Listening of SSH socket failed
1
03588
Acceptance of SSH socket failed
1
03589
Break received
1
03590
Max number of SSH connection reached
1
03591
Certificate error
1
03592
*Not used
Table 11. System Alarms and Events (Continued)
Type
Code
Identification Code
Alarm or Event