HP 11kVA 400 Volt IEC309 16A 3-Phase Input 30xC13/3xC19 HP Monitored Power Dis - Page 94

Nominal Amps: 10A, 15A, 16A, 20A

Page 94 highlights

Serial Interface Operation Table 9. PDU CLI Objects (Continued) XML Object Name PDU.Input[1].Statistic[4].Reset.Energy PDU.Input[1].Statistic[4].Reset.Time PDU.Input[1].Type PDU.MeasurementBoard.Gateway.Address PDU.MeasurementBoard.Gateway.Command Type Measure Measure Constant HideMeasure HideMeasure PDU.MeasurementBoard.Gateway.Count PDU.MeasurementBoard.Gateway.Register PDU.MeasurementBoard.Gateway.Switchable PDU.MeasurementBoard.Gateway[x].Value HideMeasure HideMeasure HideMeasure HideMeasure PDU.MeasurementBoard[x].PresentStatus.CommunicationLost Measure PDU.OutletSystem.Outlet.Count PDU.OutletSystem.Outlet[x].ConfigCurrent PDU.OutletSystem.Outlet[x].GangID PDU.OutletSystem.Outlet[x].iName PDU.OutletSystem.Outlet[x].OutletID PDU.OutletSystem.Outlet[x].PhaseID Constant Constant Constant String[31] Constant Constant Description Unit Access Energy saved at the instant the user resets the stat. Wh RO Timestamp saved at the instant the user resets the stat. s RO List types of PDU Input plugs. - RO Address of the teridian module to be accessed. - RW Write: command to the Gateway - RW 0: None 1: Read 2: Write Read: return the CR of last command to the Gateway: 0: Success 0 , Access failed for the following reasons: 1: Command Unknown. 2: Gateway not enabled. 3: Address out of range. 4: Register out of r. Number of 32 bits data to be read or write in consecutive - RW READ or WRITE request. 1 to 8. Address of the register to be read or write. - RW 0: The gateway is disabled. - RW 1: The gateway is enabled. 1 up to 8 consecutive register values can be read or write - RW with the gateway in one request. NOTE: Follow these steps to read registers from the board: 1. Write 1 in Command 2. Read Command, check it is 0 3. Read the data that had been read into Value Communication status with the acquisition card ICM & - RO SM: 0: Communication OK 1: Communication failed. Total Number of outlets - RO Nominal Amps: 10A, 15A, 16A, 20A, .. mA RO Breaker/section index where the Outlet is connected. - RO It is the x of Gang[x] collection. Outlet friendly name. - RW Numbering of the outlet into the breaker/section module. - RO 1 to 56. Phase ID that powers the outlet: - RO - 1, 2, 3 to identify a simple phase. - 12, 23, 31 to identify a composed phase. HP Monitored PDU User's Guide P-164000281-Rev 1 88

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120

Serial Interface Operation
HP Monitored PDU User’s Guide
P-164000281—Rev 1
88
PDU.Input[1].Statistic[4].Reset.Energy
Measure
Energy saved at the instant the user resets the stat.
Wh
RO
PDU.Input[1].Statistic[4].Reset.Time
Measure
Timestamp saved at the instant the user resets the stat.
s
RO
PDU.Input[1].Type
Constant
List types of PDU Input plugs.
-
RO
PDU.MeasurementBoard.Gateway.Address
HideMeasure
Address of the teridian module to be accessed.
-
RW
PDU.MeasurementBoard.Gateway.Command
HideMeasure
Write: command to the Gateway
0: None
1: Read
2: Write
Read: return the CR of last command to the Gateway:
0: Success
<> 0 , Access failed for the following reasons:
1: Command Unknown.
2: Gateway not enabled.
3: Address out of range.
4: Register out of r.
-
RW
PDU.MeasurementBoard.Gateway.Count
HideMeasure
Number of 32 bits data to be read or write in consecutive
READ or WRITE request. 1 to 8.
-
RW
PDU.MeasurementBoard.Gateway.Register
HideMeasure
Address of the register to be read or write.
-
RW
PDU.MeasurementBoard.Gateway.Switchable
HideMeasure
0: The gateway is disabled.
1: The gateway is enabled.
-
RW
PDU.MeasurementBoard.Gateway[x].Value
HideMeasure
1 up to 8 consecutive register values can be read or write
with the gateway in one request.
NOTE: Follow these steps to read registers from the board:
1. Write 1 in Command
2. Read Command, check it is 0
3. Read the data that had been read into Value
-
RW
PDU.MeasurementBoard[x].PresentStatus.CommunicationLost
Measure
Communication status with the acquisition card ICM &
SM:
0: Communication OK
1: Communication failed.
-
RO
PDU.OutletSystem.Outlet.Count
Constant
Total Number of outlets
-
RO
PDU.OutletSystem.Outlet[x].ConfigCurrent
Constant
Nominal Amps: 10A, 15A, 16A, 20A, ..
mA
RO
PDU.OutletSystem.Outlet[x].GangID
Constant
Breaker/section index where the Outlet is connected.
It is the x of Gang[x] collection.
-
RO
PDU.OutletSystem.Outlet[x].iName
String[31]
Outlet friendly name.
-
RW
PDU.OutletSystem.Outlet[x].OutletID
Constant
Numbering of the outlet into the breaker/section module.
1 to 56.
-
RO
PDU.OutletSystem.Outlet[x].PhaseID
Constant
Phase ID that powers the outlet:
- 1, 2, 3 to identify a simple phase.
- 12, 23, 31 to identify a composed phase.
-
RO
Table 9. PDU CLI Objects (Continued)
XML Object Name
Type
Description
Unit
Access