HP 11kVA 400 Volt IEC309 16A 3-Phase Input 30xC13/3xC19 HP Monitored Power Dis - Page 90

XML Object Name, Description, Access, HP Monitored PDU User's Guide, P-164000281-Rev 1

Page 90 highlights

Table 9. PDU CLI Objects (Continued) XML Object Name PDU.Gang[x].Current PDU.Gang[x].GangID PDU.Gang[x].iGang PDU.Gang[x].iName PDU.Gang[x].InputID PDU.Gang[x].OverCurrent[1].Threshold PDU.Gang[x].OverCurrent[3].Threshold PDU.Gang[x].OverCurrent[4].Threshold PDU.Gang[x].OverVoltage[1].Threshold PDU.Gang[x].OverVoltage[2].Threshold PDU.Gang[x].OverVoltage[3].Threshold PDU.Gang[x].OverVoltage[4].Threshold PDU.Gang[x].PeakFactor PDU.Gang[x].PercentLoad PDU.Gang[x].PhaseID PDU.Gang[x].Pole[1].ActivePower PDU.Gang[x].Pole[1].ApparentPower PDU.Gang[x].Pole[1].Current PDU.Gang[x].Pole[1].PeakFactor PDU.Gang[x].Pole[1].PhaseID PDU.Gang[x].Pole[1].PowerFactor PDU.Gang[x].Pole[1].ReactivePower PDU.Gang[x].Pole[1].Statistic[4].Energy PDU.Gang[x].Pole[1].Voltage PDU.Gang[x].Pole[2].ActivePower PDU.Gang[x].Pole[2].ApparentPower PDU.Gang[x].Pole[2].Current PDU.Gang[x].Pole[2].PeakFactor PDU.Gang[x].Pole[2].PhaseID PDU.Gang[x].Pole[2].PowerFactor Serial Interface Operation Type Measure Constant String[15] String[31] Constant Parameter Parameter Parameter Parameter Parameter Parameter Parameter Measure Measure Constant HideMeasure HideMeasure HideMeasure HideMeasure Constant HideMeasure HideMeasure HideMeasure HideMeasure HideMeasure HideMeasure HideMeasure HideMeasure Constant HideMeasure Description Unit Access Current provided by the breaker/section. For a double pole mA RO breaker, it is calculated as the max of the two poles current. Breaker ID = x(1,2,..) - RO Breaker/section silk-screened name. - RO Example: 'A' or 'B' .... Breaker/section friendly name. - RW Identify which Input is powering the group. This is useful - RO when the PDI is dual Input. mA RW mA RW mA RW Threshold cV RW Threshold cV RW Threshold cV RW Threshold cV RW Crest factor of the current provided by the breaker/section. m% RO A double pole breaker is calculated as the max of the two poles crest factor. Percent load consumed by the breaker/section. It is the ratio: current consumed / the nominal current. % RO Phase number that is connected to the breaker/section: 1, - RO 2, or 3. A double pole breaker is ij. Ex: 12 if the 2 phases are L1 and L2. Active Power provided by the pole. dW RO Apparent Power provided by the pole. dVA RO Current provided by the pole. mA RO Crest factor of the current provided by the pole. m% RO Phase number that is connected to the pole: 1, 2, or 3. - RO Ratio of active power / apparent power provided by the pole of the breaker or outlet section. m% RO Reactive Power provided by the pole. dVA RO R Energy counter since last reset. As it is reset to 0, the Wh RO related timestamp is updated with the current RTC value. Voltage Measured on the pole. cV RO Active Power provided by the pole. dW RO Apparent Power provided by the pole. dVA RO Current Power provided by the pole. mA RO Crest factor of the current provided by the pole. m% RO Phase number that is connected to the pole: 1, 2, or 3. - RO Ratio of active power / apparent power provided by the pole of the breaker or outlet section. m% RO HP Monitored PDU User's Guide P-164000281-Rev 1 84

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120

Serial Interface Operation
HP Monitored PDU User’s Guide
P-164000281—Rev 1
84
PDU.Gang[x].Current
Measure
Current provided by the breaker/section. For a double pole
breaker, it is calculated as the max of the two poles
current.
mA
RO
PDU.Gang[x].GangID
Constant
Breaker ID = x(1,2,..)
-
RO
PDU.Gang[x].iGang
String[15]
Breaker/section silk-screened name.
Example: 'A' or 'B' ….
-
RO
PDU.Gang[x].iName
String[31]
Breaker/section friendly name.
-
RW
PDU.Gang[x].InputID
Constant
Identify which Input is powering the group. This is useful
when the PDI is dual Input.
-
RO
PDU.Gang[x].OverCurrent[1].Threshold
Parameter
mA
RW
PDU.Gang[x].OverCurrent[3].Threshold
Parameter
mA
RW
PDU.Gang[x].OverCurrent[4].Threshold
Parameter
mA
RW
PDU.Gang[x].OverVoltage[1].Threshold
Parameter
Threshold
cV
RW
PDU.Gang[x].OverVoltage[2].Threshold
Parameter
Threshold
cV
RW
PDU.Gang[x].OverVoltage[3].Threshold
Parameter
Threshold
cV
RW
PDU.Gang[x].OverVoltage[4].Threshold
Parameter
Threshold
cV
RW
PDU.Gang[x].PeakFactor
Measure
Crest factor of the current provided by the breaker/section.
A double pole breaker is calculated as the max of the two
poles crest factor.
m%
RO
PDU.Gang[x].PercentLoad
Measure
Percent load consumed by the breaker/section. It is the
ratio: current consumed / the nominal current.
%
RO
PDU.Gang[x].PhaseID
Constant
Phase number that is connected to the breaker/section: 1,
2, or 3.
A double pole breaker is ij.
Ex: 12 if the 2 phases are L1 and L2.
-
RO
PDU.Gang[x].Pole[1].ActivePower
HideMeasure
Active Power provided by the pole.
dW
RO
PDU.Gang[x].Pole[1].ApparentPower
HideMeasure
Apparent Power provided by the pole.
dVA
RO
PDU.Gang[x].Pole[1].Current
HideMeasure
Current provided by the pole.
mA
RO
PDU.Gang[x].Pole[1].PeakFactor
HideMeasure
Crest factor of the current provided by the pole.
m%
RO
PDU.Gang[x].Pole[1].PhaseID
Constant
Phase number that is connected to the pole: 1, 2, or 3.
-
RO
PDU.Gang[x].Pole[1].PowerFactor
HideMeasure
Ratio of active power / apparent power provided by the
pole of the breaker or outlet section.
m%
RO
PDU.Gang[x].Pole[1].ReactivePower
HideMeasure
Reactive Power provided by the pole.
dVA
R
RO
PDU.Gang[x].Pole[1].Statistic[4].Energy
HideMeasure
Energy counter since last reset. As it is reset to 0, the
related timestamp is updated with the current RTC value.
Wh
RO
PDU.Gang[x].Pole[1].Voltage
HideMeasure
Voltage Measured on the pole.
cV
RO
PDU.Gang[x].Pole[2].ActivePower
HideMeasure
Active Power provided by the pole.
dW
RO
PDU.Gang[x].Pole[2].ApparentPower
HideMeasure
Apparent Power provided by the pole.
dVA
RO
PDU.Gang[x].Pole[2].Current
HideMeasure
Current Power provided by the pole.
mA
RO
PDU.Gang[x].Pole[2].PeakFactor
HideMeasure
Crest factor of the current provided by the pole.
m%
RO
PDU.Gang[x].Pole[2].PhaseID
Constant
Phase number that is connected to the pole: 1, 2, or 3.
-
RO
PDU.Gang[x].Pole[2].PowerFactor
HideMeasure
Ratio of active power / apparent power provided by the
pole of the breaker or outlet section.
m%
RO
Table 9. PDU CLI Objects (Continued)
XML Object Name
Type
Description
Unit
Access