HP 11kVA 400 Volt IEC309 16A 3-Phase Input 30xC13/3xC19 HP Monitored Power Dis - Page 113
Type Code, Identification and, Index Code, Alarm or Event, Description
View all HP 11kVA 400 Volt IEC309 16A 3-Phase Input 30xC13/3xC19 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 113 highlights
Maintenance and Alarms Table 12. PDU and User Alarms and Events (Continued) Identification and Type Code Index Code Alarm or Event 2 222100 PDU Gang Phase Low Voltage Warning 2 222200 PDU Gang Phase Low Voltage Critical Description The specified section voltage reading is less than the value configured as the low voltage warning threshold. The specified section voltage reading is less than the value configured as the low voltage critical threshold. 2 222300 2 222400 2 241000 2 241100 3 300100 3 300200 3 300300 3 300400 3 300500 3 300600 3 300700 3 300800 3 300900 3 301000 3 301100 3 301200 3 301300 3 301400 3 301500 3 301600 3 301700 3 301800 3 301900 3 302000 PDU Gang Phase Over Voltage Warning PDU Gang Phase Over Voltage Critical Communication OK Communication Lost Communication module restarted Ethernet cable connected Ethernet cable not connected Factory reset requested by Ethernet card restart requested by Switch to bootloader mode for upgrade by PDU & System Log cleared Daisy Chain device does not answer Time changed Daisy chain device connected Daisy chain device disconnected Upgrade request by user Sensor connected Sensor disconnected Send mail test by user User logged in User logged out User logged in FTP User logged out FTP User failed to log FTP The specified section voltage reading is less than the value configured as the over voltage warning threshold. The specified section voltage reading is less than the value configured as the over voltage critical threshold. No communication failure detected on Teridian RS-485 bus Communication failure detected on Teridian RS-485 bus The communication module has been restarted by the user. The Ethernet cable is connected. The Ethernet cable is not connected. A factory reset has been requested through the specified user interface. An Ethernet card restart has been requested through the specified user interface. A Switch to bootloader mode for upgrade has been requested through the specified user interface. The PDU & System Log have been cleared. The Daisy Chain device does not answer. The time was changed by the user. The daisy chain device is connected. The daisy chain device is disconnected. An upgrade was requested by the user. The sensor was connected. The sensor was disconnected. The user sent a mail test. The specified user logged in by the specified protocol. The specified user logged out by the specified protocol. The specified user logged in by FTP. The specified user logged out by FTP. The specified user failed to log by FTP. HP Monitored PDU User's Guide P-164000281-Rev 1 107