HP Brocade 8/12c Brocade Fabric OS Troubleshooting and Diagnostics Guide v6.2. - Page 103

Working With Diagnostic Features, FTRACE concepts

Page 103 highlights

FTRACE concepts 10 | | | |Trace Header| Wrap | In | Out | Switch | Switch | | Id | State | Size | Address | Count | OXID | OXID | Date | Time | | 0| unused | 200000 | 0x10010000 | 0 | FFFF | FFFF | | | | 1| Current | 200000 | 0x10010100 | 0 | FFFF | FFFF | | | | 2| unused | 200000 | 0x10010200 | 0 | FFFF | FFFF | | | | 3| unused | 200000 | 0x10010300 | 0 | FFFF | FFFF | | | 6. Transfer the FTRACE information off of the switch. Refer to Chapter 13, "Working With Diagnostic Features" for more information on saving comprehensive diagnostic files to the server. Fabric OS Troubleshooting and Diagnostics Guide 87 53-1001187-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144

Fabric OS Troubleshooting and Diagnostics Guide
87
53-1001187-01
FTRACE concepts
10
|
|
|
|Trace Header|
Wrap
| In
| Out
|
Switch
|
Switch
|
|
Id |
State
|
Size
|
Address
|
Count
| OXID | OXID |
Date
|
Time
|
+-----+-------------+--------+------------+------------+------+------+-------------+----------+
|
0 |
unused | 200000 | 0x10010000 |
0 | FFFF | FFFF |
|
|
|
1 |
Current | 200000 | 0x10010100 |
0 | FFFF | FFFF |
|
|
|
2 |
unused | 200000 | 0x10010200 |
0 | FFFF | FFFF |
|
|
|
3 |
unused | 200000 | 0x10010300 |
0 | FFFF | FFFF |
|
|
+-----+-------------+--------+------------+------------+------+------+-------------+----------+
6.
Transfer the FTRACE information off of the switch.