HP Brocade 8/12c Brocade Fabric OS Troubleshooting and Diagnostics Guide v6.2. - Page 110

Troubleshooting FICON NPIV

Page 110 highlights

11 Troubleshooting FICON NPIV Symptom Mainframe RMF utility fails to capture performance data Probable cause and recommended action In Fabric OS v6.0.0, Brocade SilkWorm switches do not fully implement all CUP commands needed to collect all performance data on a switch. Upgrade your switch to Fabric OS v6.1.0, where the performance data is captured. Troubleshooting FICON NPIV You should capture all pertinent data from the "General information to gather for all cases" on page 90 and "Gathering additional information" on page 92. NPIV licenses must be installed on v5.0.x. There is no license requirement for Fabric OS v5.1.0 and above. 94 Fabric OS Troubleshooting and Diagnostics Guide 53-1001187-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144

94
Fabric OS Troubleshooting and Diagnostics Guide
53-1001187-01
Troubleshooting FICON NPIV
11
Symptom
Mainframe RMF utility fails to capture performance data
Probable cause and recommended action
In Fabric OS v6.0.0, Brocade SilkWorm switches do not fully implement all CUP commands needed
to collect all performance data on a switch. Upgrade your switch to Fabric OS v6.1.0, where the
performance data is captured.
Troubleshooting FICON NPIV
You should capture all pertinent data from the
“General information to gather for all cases”
on
page 90 and
“Gathering additional information”
on page 92.
NPIV licenses must be installed on v5.0.x. There is no license requirement for Fabric OS v5.1.0 and
above.