HP Brocade 8/12c Brocade Fabric OS Troubleshooting and Diagnostics Guide v6.2. - Page 96

Port mirroring considerations, TABLE 13

Page 96 highlights

10 Port mirroring • FC4-16 16-port blade • FC4-48 48-port blade • FC8-16 16-port blade • FC8-32 32-port blade • FC8-48 48-port blade • FA4-18 application blade • FR4-18i routing and FCIP blade • FC4-16IP iSCSI blade on Fibre Channel ports only The FC4- and FC8-48 implement port pairing, meaning that two ports share the same area. Port pairing uses a single area to map to two physical ports. A frame destined to the secondary port is routed to the primary port. The primary port's filtering zone engine is used to redirect the frame to the secondary port. Port mirroring uses the port filter zone engine to redirect the frames to the mirror port. If two F_Ports share the same area, both ports cannot be part of a mirror connection. One of the two ports can be part of the connection as long as the other port is offline. Supported port configurations are shown in Table 13. TABLE 13 Port combinations for port mirroring Primary port Secondary port Supported F_Port F_Port No F_Port Offline Yes Offline F_Port Yes F_Port E_Port Yes E_Port F_Port Yes E_Port E_Port No If IOD is enabled, adding or deleting a port mirror connection causes a frame drop. Port mirroring reroutes a given connection to the mirror port, where the mirror traffic takes an extra route to the mirror port. When the extra route is removed, the frames between the two ports goes directly to the destination port. Since the frames at the mirror port could be queued at the destination port behind those frames that went directly to the destination port, port mirroring drops those frames from the mirror port when a connection is disabled. If IOD has been disabled, port mirroring does not drop any frames but displays an IOD error. • A port cannot be mirrored to multiple locations. If you define multiple mirror connections for the same F_Port, all the connections must share the same mirror port. • Local switches cannot be mirrored because FICON CUP frames to a local switch are treated as well-known addresses or embedded frame traffic. • Using firmware download to downgrade to previous Fabric OS releases that do not support port mirroring requires that you remove all port mirroring connections. Port mirroring considerations Before creating port mirror connections, consider the following limitations: • A mirror port can be any port on the same switch as the source identifier port. • Only one domain can be mirrored per chip; after a domain is defined, only mirror ports on the defined domain can be used. 80 Fabric OS Troubleshooting and Diagnostics Guide 53-1001187-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144

80
Fabric OS Troubleshooting and Diagnostics Guide
53-1001187-01
Port mirroring
10
FC4-16 16-port blade
FC4-48 48-port blade
FC8-16 16-port blade
FC8-32 32-port blade
FC8-48 48-port blade
FA4-18 application blade
FR4-18i routing and FCIP blade
FC4-16IP iSCSI blade on Fibre Channel ports only
The FC4- and FC8-48 implement port pairing, meaning that two ports share the same area.
Port pairing uses a single area to map to two physical ports. A frame destined to the secondary
port is routed to the primary port. The primary port's filtering zone engine is used to redirect
the frame to the secondary port. Port mirroring uses the port filter zone engine to redirect the
frames to the mirror port. If two F_Ports share the same area, both ports cannot be part of a
mirror connection. One of the two ports can be part of the connection as long as the other port
is offline. Supported port configurations are shown in
Table 13
.
If IOD is enabled, adding or deleting a port mirror connection causes a frame drop. Port
mirroring reroutes a given connection to the mirror port, where the mirror traffic takes an extra
route to the mirror port. When the extra route is removed, the frames between the two ports
goes directly to the destination port. Since the frames at the mirror port could be queued at the
destination port behind those frames that went directly to the destination port, port mirroring
drops those frames from the mirror port when a connection is disabled. If IOD has been
disabled, port mirroring does not drop any frames but displays an IOD error.
A port cannot be mirrored to multiple locations. If you define multiple mirror connections for
the same F_Port, all the connections must share the same mirror port.
Local switches cannot be mirrored because FICON CUP frames to a local switch are treated as
well-known addresses or embedded frame traffic.
Using firmware download to downgrade to previous Fabric OS releases that do not support port
mirroring requires that you remove all port mirroring connections.
Port mirroring considerations
Before creating port mirror connections, consider the following limitations:
A mirror port can be any port on the same switch as the source identifier port.
Only one domain can be mirrored per chip; after a domain is defined, only mirror ports on the
defined domain can be used.
TABLE 13
Port combinations for port mirroring
Primary port
Secondary port
Supported
F_Port
F_Port
No
F_Port
Offline
Yes
Offline
F_Port
Yes
F_Port
E_Port
Yes
E_Port
F_Port
Yes
E_Port
E_Port
No