HP Brocade 8/12c Brocade Fabric OS Troubleshooting and Diagnostics Guide v6.2. - Page 49

primary port goes offline., command on the secondary port after

Page 49 highlights

Device login issues 3 NOTE When two shared ports on an FC4-48 blade are receiving traffic and the primary port goes offline, all the frames that are out for delivery for the primary port are dropped, but the counters show them as dropped on the secondary port that shares the same area. Error counters increment unexpectedly for the secondary port, but the secondary port is operating properly. If this occurs, clear the counters using the portStatsClear command on the secondary port after the primary port goes offline. 5. Enter the portFlagsShow command; then, check to see how a port has logged in and where a login failed (if a failure occurred): switch:admin> portflagsshow Port SNMP Physical Flags 0 Offline In_Sync PRESENT U_PORT LED 1 Online In_Sync PRESENT ACTIVE F_PORT G_PORT U_PORT LOGICAL_ONLINE LOGIN NOELP LED ACCEPT 2 Offline No_Light PRESENT U_PORT LED 3 Offline No_Module PRESENT U_PORT LED 4 Offline No_Module PRESENT U_PORT LED 5 Offline No_Light PRESENT U_PORT LED 6 Offline No_Module PRESENT U_PORT LED 7 Offline No_Module PRESENT U_PORT LED 8 Offline No_Light PRESENT U_PORT LED 9 Offline No_Light PRESENT U_PORT LED 10 Offline No_Module PRESENT U_PORT LED 11 Offline No_Module PRESENT U_PORT LED 12 Offline No_Module PRESENT U_PORT LED 13 Offline No_Module PRESENT U_PORT LED 14 Online In_Sync PRESENT ACTIVE F_PORT G_PORT U_PORT LOGICAL_ONLINE LOGIN NOELP LED ACCEPT 15 Online In_Sync PRESENT ACTIVE E_PORT G_PORT U_PORT SEGMENTED LOGIN LED 6. Enter the portLogDumpPort portid command where the port ID is the port number; then, view the device-to-switch communication. switch:admin> portlogdumpport 8 | more time task event port cmd args Thu Nov 6 16:52:39 2008 16:52:39.066 PORT scn 8 1 00010004,4302000f,02000000 16:52:39.066 PORT scn 8 2 ce3dfab0,d9672800,00000002 16:52:39.066 PORT scn 8 2 ce3dfab0,d9672800,00000080 16:52:39.066 PORT scn 8 5 00000000,00000000,00000002 16:52:39.066 PORT scn 8 1 00010004,4302000f,00000002 16:52:39.066 PORT scn 8 1 00010004,4302000f,02000000 16:52:39.071 PORT ioctl 88010004 1,0 * 4 16:52:42.311 SPEE sn 8 WS 00000000,00000000,00000000 16:52:42.558 SPEE sn 8 NM 00000000,00000000,00000000 16:52:42.558 SPEE sn 8 NF 00000000,00000000,00000000 16:52:42.558 SPEE sn 8 NC 00000001,00000000,00000000 16:52:42.559 LOOP loopscn 8 LIP 8002 16:52:42.559 LOOP loopscn 8 LIP f7f7 16:52:42.572 LOOP loopscn 8 LIM 0 16:52:42.572 PORT Tx3 8 12 22000000,00000000,ffffffff,11010000 16:52:42.572 PORT Rx3 8 12 22000000,00000000,ffffffff,11010000 Fabric OS Troubleshooting and Diagnostics Guide 33 53-1001187-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144

Fabric OS Troubleshooting and Diagnostics Guide
33
53-1001187-01
Device login issues
3
NOTE
When two shared ports on an FC4-48 blade are receiving traffic and the primary port goes offline,
all the frames that are out for delivery for the primary port are dropped, but the counters show them
as dropped on the secondary port that shares the same area. Error counters increment
unexpectedly for the secondary port, but the secondary port is operating properly.
If this occurs, clear the counters using the
portStatsClear
command on the secondary port after the
primary port goes offline.
5.
Enter the
portFlagsShow
command; then, check to see how a port has logged in and where a
login failed (if a failure occurred):
switch:admin>
portflagsshow
Port SNMP
Physical
Flags
-------------------------------
0 Offline
In_Sync
PRESENT U_PORT LED
1 Online
In_Sync
PRESENT ACTIVE F_PORT G_PORT U_PORT LOGICAL_ONLINE
LOGIN NOELP LED ACCEPT
2 Offline
No_Light
PRESENT U_PORT LED
3 Offline
No_Module
PRESENT U_PORT LED
4 Offline
No_Module
PRESENT U_PORT LED
5 Offline
No_Light
PRESENT U_PORT LED
6 Offline
No_Module
PRESENT U_PORT LED
7 Offline
No_Module
PRESENT U_PORT LED
8 Offline
No_Light
PRESENT U_PORT LED
9 Offline
No_Light
PRESENT U_PORT LED
10 Offline
No_Module
PRESENT U_PORT LED
11 Offline
No_Module
PRESENT U_PORT LED
12 Offline
No_Module
PRESENT U_PORT LED
13 Offline
No_Module
PRESENT U_PORT LED
14 Online
In_Sync
PRESENT ACTIVE F_PORT G_PORT U_PORT LOGICAL_ONLINE
LOGIN NOELP LED ACCEPT
15 Online
In_Sync
PRESENT ACTIVE E_PORT G_PORT U_PORT SEGMENTED LOGIN
LED
6.
Enter the
portLogDumpPort
portid
command where the port ID is the port number; then, view
the device-to-switch communication.
switch:admin> portlogdumpport 8 | more
time
task
event
port cmd
args
-------------------------------------------------
Thu Nov
6 16:52:39 2008
16:52:39.066 PORT
scn
8
1
00010004,4302000f,02000000
16:52:39.066 PORT
scn
8
2
ce3dfab0,d9672800,00000002
16:52:39.066 PORT
scn
8
2
ce3dfab0,d9672800,00000080
16:52:39.066 PORT
scn
8
5
00000000,00000000,00000002
16:52:39.066 PORT
scn
8
1
00010004,4302000f,00000002
16:52:39.066 PORT
scn
8
1
00010004,4302000f,02000000
16:52:39.071 PORT
ioctl
88010004
1,0 * 4
16:52:42.311 SPEE
sn
8
WS
00000000,00000000,00000000
16:52:42.558 SPEE
sn
8
NM
00000000,00000000,00000000
16:52:42.558 SPEE
sn
8
NF
00000000,00000000,00000000
16:52:42.558 SPEE
sn
8
NC
00000001,00000000,00000000
16:52:42.559 LOOP
loopscn
8
LIP
8002
16:52:42.559 LOOP
loopscn
8
LIP
f7f7
16:52:42.572 LOOP
loopscn
8
LIM
0
16:52:42.572 PORT
Tx3
8
12
22000000,00000000,ffffffff,11010000
16:52:42.572 PORT
Rx3
8
12
22000000,00000000,ffffffff,11010000