HP FAX-750 Service Manual - Page 124

called stations, both at the calling

Page 124 highlights

Selector No. 1 2 3 4 5 6 7 8 WSW18 (Function setting 3) Function Not used. Detection enabled time for CNG and no tone Not used. Registration of station ID Tone sound monitoring Setting and Specifications No. 2 0 0 1 1 3 0: 1: 0: 1: 40 sec. 0 sec. 5 sec. 80 sec. (No detection) 0: No. 7 0 1 1 Permitted 1: Prohibited 8 X: 0: 1: No monitoring Up to phase B at the calling station only All transmission phases both at the calling and called stations l Selectors 2 and 3: Detection enabled time for CNG and no tone After the line is connected via the external telephone or by picking up the handset of the facsimile equipment, the equipment can detect a CNG signal or no tone for the time length specified by these selectors. The setting specified by these selectors becomes effective only when selector 8 of WSW20 is set to "1." l Selector 6: Registration of station ID Setting this selector to "0" permits the registration of station ID for Austrian and Czech versions. l Selectors 7 and 8: Tone sound monitoring These selectors set monitoring specifications of the tone sound inputted from the line. V - 31

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218

V
- 31
WSW18
(Function setting 3)
Selector
No.
Function
Setting and Specifications
1
Not used.
2
3
Detection enabled time for CNG
and no tone
No. 2
3
0
0
:
40 sec.
0
1
:
0 sec.
(No detection)
1
0
:
5 sec.
1
1
:
80 sec.
4
5
Not used.
6
Registration of station ID
0:
Permitted
1:
Prohibited
7
8
Tone sound monitoring
No. 7
8
0
X
:
No monitoring
1
0
:
Up to phase B at the
calling station only
1
1
:
All transmission phases
both at the calling and
called stations
Selectors 2 and 3:
Detection enabled time for CNG and no tone
After the line is connected via the external telephone or by picking up the handset of the facsimile
equipment, the equipment can detect a CNG signal or no tone for the time length specified by these
selectors.
The setting specified by these selectors becomes effective only when selector 8 of
WSW20 is set to "1."
Selector 6:
Registration of station ID
Setting this selector to "0" permits the registration of station ID for Austrian and Czech versions.
Selectors 7 and 8:
Tone sound monitoring
These selectors set monitoring specifications of the tone sound inputted from the line.