HP StorageWorks 2/64 HP StorageWorks Core Switch 2/64 Getting Started & Ge - Page 61

m FC Cable LC duplex M/M

Page 61 highlights

Table 4. LC to LC Cables Used with the HP StorageWorks Core Switch 2/64 LC - LC Cable Connectors Product Number Part Number Description C7524A C7525A C7526A C7527A 5065-5101 5065-5102 5065-5103 5065-5104 2m FC Cable LC duplex M/M 16m FC Cable LC duplex M/M 50m FC Cable LC duplex M/M 200m FC Cable LC duplex M/M Two items are provided to assist with cable management: • Cable Management Tray The Cable Management Tray is attached to the bottom of the chassis and can be used to route the power cables and other cables down below the chassis. • Cable Guides A set of 16 cable guides are provided with the HP StorageWorks Core Switch 2/64 and can be used to organize the port cables into logical groups, such as according to port quads (sets of four neighboring ports). The cable guides are free-floating and do not attach to the chassis. The cable guides serve to keep the cables evenly spaced and to hold them away from the 16-port cards to make card replacement easier and to prevent the cables from bending to less than the minimum bend radius. CAUTION Do not route the cables in front of the air exhaust vent, which is located at the top of the port side of the chassis. The minimum bend radius for a 50-micron cable is 2 inches under full tensile load and 1.2 inches with no tensile load. Tie wraps are not recommended for optical cables because they are easily overtightened. Operating the Switch 53

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94

Operating the Switch
53
Two items are provided to assist with cable management:
Cable Management Tray
The Cable Management Tray is attached to the bottom of the chassis and
can be used to route the power cables and other cables down below the
chassis.
Cable Guides
A set of 16 cable guides are provided with the HP StorageWorks Core
Switch 2/64 and can be used to organize the port cables into logical
groups, such as according to port quads (sets of four neighboring ports).
The cable guides are free-floating and do not attach to the chassis. The
cable guides serve to keep the cables evenly spaced and to hold them
away from the 16-port cards to make card replacement easier and to
prevent the cables from bending to less than the minimum bend radius.
CAUTION
Do not route the cables in front of the air exhaust vent, which is
located at the top of the port side of the chassis.
The minimum bend radius for a 50-micron cable is 2 inches under full
tensile load and 1.2 inches with no tensile load.
Tie wraps are not recommended for optical cables because they are easily
overtightened.
Table 4.
LC to LC Cables Used with the HP StorageWorks Core Switch 2/64
LC - LC Cable Connectors
Product Number
Part Number
Description
C7524A
5065-5101
2m FC Cable LC duplex M/M
C7525A
5065-5102
16m FC Cable LC duplex M/M
C7526A
5065-5103
50m FC Cable LC duplex M/M
C7527A
5065-5104
200m FC Cable LC duplex M/M