Check Power LED., Center LED
View all HP StorageWorks 2/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 70 highlights
Table 7. Power Supply LED Patterns Location of LED Purpose of LED Color of LED Status of Hardware Recommended Action Upper LED Power No light (LED is off) Power supply does not have Ensure power supply is incoming power and is not firmly seated, switch has providing power to switch. incoming power, both power cables are connected, and AC power switches are on. Steady green Power has incoming power No action required. and is providing power to switch. Center LED Predictive No light Failure (LED is off) ! Flashing orange (amber) Power supply is either healthy or does not have incoming power. Power supply is about to fail due to a failing fan inside the power supply. Check Power LED. Replace power supply. Lower LED Fail ! No light (LED is off) Power supply is either healthy or does not have incoming power. Check Power LED. Steady orange (amber) Either the switch has power but this power supply does not (AC switch may be off) or the power supply has failed. Ensure correct AC power switch is on and power supply is seated. If orange light continues, replace power supply. Flashing orange (amber) Power supply is unable to supply power. Verify incoming power meets requirements listed in "Power Specifications" on page 71. 62 getting started and general reference guide