HP StorageWorks 2/64 HP StorageWorks Core Switch 2/64 Getting Started & Ge - Page 81
Environmental, 0°C to 40°C
View all HP StorageWorks 2/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 81 highlights
Environmental The following table lists the acceptable environmental ranges. The requirements for non-operating conditions are also provided for acceptable storage and transportation environments. Table 13. Environmental Requirements Condition Acceptable Range Temperature (operating)* 0°C to 40°C (32°F to 104°F) Temperature (non-operating) -35°C to 65°C (-31°F to 149°F) Humidity (operating) 5% to 85% RH non-condensing, at 40°C Humidity (non-operating) 0% to 90% RH non-condensing, at 40°C Altitude (operating) 0 to 3 km above sea level (1 to 10,000 ft. altitude) Altitude (non-operating) 0 to 12 km above sea level (1 to 39,370 ft. altitude) Shock (operating) 4 G, 11 MS duration, half-sine wave Shock (non-operating) 20 G, 11 MS duration, sq. wave Vibration (operating) 5 G, 0-3 kHz at 1.0 octave/minute Vibration (non-operating) 10 G, 0-5 kHz at 1.0 octave/minute Heat Dissipation 64 ports: 3690 BTU/hr. 128 ports: 6700 BTU/hr. *The 0-40°C temperature range is for the chassis. Individual components may have a higher range. For example, the 16-port cards and CP cards have a temperature range up to 75°C. Use the tempShow or Fabric Watch commands to show temperature status of all components. Specifications 73