HP StorageWorks 2/64 HP StorageWorks Core Switch 2/64 Getting Started & Ge - Page 72
LEDs on the WWN Card and Bezel, on 2 second
![]() |
View all HP StorageWorks 2/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 72 highlights
Table 8. Blower Assembly LED Patterns Location of LED Purpose of LED Color of LED Status of Hardware Recommended Action Right LED Fault No light (LED is off) Blower assembly is either healthy or does not have incoming power. Ensure blower assembly has incoming power. Steady orange Blower assembly has fully Replace blower assembly. or partly failed. Slow-flashing orange: on 2 second; off 2 second Blower assembly is not seated correctly or is faulty. Pull unit out and reseat. If LED continues to flash, replace unit. Fast-flashing Environmental range orange: exceeded. on 1/2 second; off 1/2 second Check for out-of-bounds environmental condition. LEDs on the WWN Card and Bezel The WWN card and bezel are located at the top of the blower assembly side of the chassis. The bezel covers the card, allowing the LEDs to shine through. The bezel and card provide a consolidated LED view of: • The incoming power to and status of the 16-port cards in slots 1-4 and 7-10 • The incoming power to and status of the CP cards in slots 5 and 6 • The incoming power to the four power supplies If a slot has a filler panel in place of a 16-port card, CP card, or power supply, the LEDs for that slot on the WWN card and bezel do not light up. Note If a Status or Fail LED on the WWN card flashes, the Power LED on the WWN card also flashes for increased visibility. The LEDs patterns may temporarily change during POST and other diagnostic tests. 64 getting started and general reference guide
![](/manual_guide/products/hewlettpackard-storageworks-264-hp-storageworks-core-switch-264-getting-started-general-reference-guide-4e71e98/72.png)