HP StorageWorks MSA1000 HP StorageWorks 2/8q Fibre Channel Switch Management V - Page 153
Show Setup command, domain_id], the system displays routes for all switches in the fabric.
View all HP StorageWorks MSA1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 153 highlights
Command Line Interface Table 57: Show Port parameters (Continued) Entry Link Failures Login Logout LoopTimeouts LossOfSync PrimSeqErrors RxLinkResets RxOfflineSeq TotalErrors TotalLIPsRecvd TotalLIPsXmitd TotalLinkResets TotalOfflineSeq TotalRxFrames TotalRxWords TotalTxFrames TotalTxWords TxLinkResets TxOfflineSeq Description Number of optical link failures detected by this port. A link failure is a loss of synchronization or a loss of signal while not in the offline state. A loss of signal causes the switch to attempt to re-establish the link. If the link is not re-established, a link failure is counted. A link reset is performed after a link failure. Number of device logins Number of device logouts A two (2) second timeout as specified by FC-AL-2. Number of synchronization losses (>100 ms) detected by this port. A loss of synchronization is detected by receipt of an invalid transmission word. Primitive sequence errors detected. Number of link reset primitives received from an attached device. Number of offline sequences received. An OLS is issued for link initialization, a Receive & Recognize Not_Operational (NOS) state, or to enter the offline state. Total number of errors detected. Number of loop initialization primitive frames received by this port. Number of loop initialization primitive frames transmitted by this port. Total number of link reset primitives. Total number of Offline Sequences issued and received by this port. Total number of frames received by this port. Total number of words received by this port. Total number of frames issued by this port. Total number of words issued by this port. Number of Link Resets issued by this port. Total number of Offline Sequences issued by this port. post log Displays the Power On Self Test (POST) log which contains results from the POST. setup [option] Displays setup attributes for the system, SNMP, and the switch manufacturer. See the "Show Setup command" on page 166. steering [domain_id] Displays the routes that data takes to the switch given by [domain_id]. If you omit [domain_id], the system displays routes for all switches in the fabric. HP StorageWorks 2/8q Fibre Channel Switch Management User Guide 153