HP StorageWorks MSA1000 HP StorageWorks 2/8q Fibre Channel Switch Management V - Page 169

Shutdown command, Test command

Page 169 highlights

Command Line Interface Shutdown command Terminates all data transfers on the switch at convenient points and closes the Telnet session. Always power cycle the switch after entering this command. Authority Admin Syntax SHUTDOWN Notes Always use this command to perform an orderly shut down before removing power from the switch. When the shutdown is complete, the Heartbeat LED is extinguished. Test command Tests ports using internal (SerDes level), external (transceiver), and online loopback tests. Internal and external tests require that the port be placed in diagnostic mode. See the "Set command" on page 135 for information about changing the port administrative state. While the test is running, the remaining ports on the switch remain fully operational. Authority Admin Syntax TEST Keywords PORT [port_number] [test_type] Tests the port given by [port_number] using the test given by [test_type]. If you omit [test_type], Internal is used. [test_type] can have the following values: internal-Tests the SerDes. This is the default. The port must be in diagnostics mode to perform this test. external-Tests both the SerDes and transceiver. The port must be in diagnostics mode to perform this test, and a loopback plug must be installed in the transceiver. online-Tests communications between the port and its device node or device loop. The port being tested must be online and connected to a remote device. The port passes if the test frame that was sent by the ASIC matches the frame that is received. This test does not disrupt communication on the port. CANCEL-Cancels the online test in progress. STATUS-Displays the status of a test in progress, or if there is no test in progress, the status of the test that was executed last. Examples To run an internal or external port test: 1. To start an admin session, enter the following command: admin start HP StorageWorks 2/8q Fibre Channel Switch Management User Guide 169

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188

Command Line Interface
169
HP StorageWorks 2/8q Fibre Channel Switch Management User Guide
Shutdown
command
Terminates all data transfers on the switch at convenient points and closes the Telnet session.
Always power cycle the switch after entering this command.
Authority
Admin
Syntax
SHUTDOWN
Notes
Always use this command to perform an orderly shut down before removing power from
the switch.
When the shutdown is complete, the Heartbeat LED is extinguished.
Test
command
Tests ports using internal (SerDes level), external (transceiver), and online loopback tests.
Internal and external tests require that the port be placed in diagnostic mode. See the “
Set
command
” on page 135 for information about changing the port administrative state. While
the test is running, the remaining ports on the switch remain fully operational.
Authority
Admin
Syntax
TEST
Keywords
PORT [port_number]
[test_type]
Tests the port given by [port_number] using the test given by [test_type]. If you omit
[test_type], Internal is used. [test_type] can have the following values:
internal
—Tests the SerDes. This is the default. The port must be in diagnostics
mode to perform this test.
external
—Tests both the SerDes and transceiver. The port must be in diagnostics
mode to perform this test, and a loopback plug must be installed in the transceiver.
online
—Tests communications between the port and its device node or device loop.
The port being tested must be online and connected to a remote device. The port
passes if the test frame that was sent by the ASIC matches the frame that is received.
This test does not disrupt communication on the port.
CANCEL
—Cancels the online test in progress.
STATUS
—Displays the status of a test in progress, or if there is no test in progress,
the status of the test that was executed last.
Examples
To run an internal or external port test:
1.
To start an admin session, enter the following command:
admin start