portLoopbackTest, FAULTY, switch:admin> diagShow, Diagnostics Status

Page 124 highlights

switch:admin> diagShow Diagnostics Status: Sun Jan 1 00 : 00 : 00 2000 Port number: 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 diags: OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK state: UP UP UP UP UP UP UP UP UP UP UP UP UP UP UP UP lm0: lm1: lm2: lm3: lm4: lm5: lm6: lm7: lm8: lm9: lm10: lm11: lm12: lm13: lm14: lm15: 39624101 39309877 39750791 39501243 40066092 40075160 39886034 39989371 40257892 39154671 39767848 40009605 39961890 39799377 40252478 40132745 frTx frTx frTx frTx frTx frTx frTx frTx frTx frTx frTx frTx frTx frTx frTx frTx 40128685 40007305 39885106 40065867 39501463 40257190 39751716 39960595 40075855 40250787 39798346 39312144 39990666 39768879 39156315 39628100 frRx frRx frRx frRx frRx frRx frRx frRx frRx frRx frRx frRx frRx frRx frRx frRx Central Memory OK Total Diag Frames Tx: 419264 Total Diag Frames Rx: 447200 Figure 54. diagShow command example Table 34. diagShow command field descriptions Field Description Diagnostics status The title header displays the time the diagShow command was performed. port# The port number. diags The current diagnostic status of the port. Possible values include OK, BAD. state The current state of the port. Possible values include UP (active), DN (inactive). lm0-7 (8-port) lm0-15 (16-port) The frame counts of active ports. The display shows the number of frames transmitted and received and low level interface counts (LLI_errs). Central Memory The central memory status. Possible values include OK, FAULTY. Total diag frames Tx The total diagnostics frames transmitted (Tx) since the last startup. This number usually corresponds to the total frames received (Rx) but may differ because of failure modes. Total Diag Frames Rx The total diagnostics frames received (Rx) since the last startup. This number usually corresponds to the total frames transmitted (Tx) but may differ because of failure modes. portLoopbackTest Figure 55 on page 109 shows the portLoopbackTest command, which verifies the intended functional operation of the switch by sending frames from the transmitter 108 IBM SAN Fibre Channel Switch: 2109 Model S16 Installation and Service Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178

Table 34. diagShow command field descriptions
Field
Description
Diagnostics status
The title header displays the time the
diagShow
command was
performed.
port#
The port number.
diags
The current diagnostic status of the port. Possible values include
OK
,
BAD
.
state
The current state of the port. Possible values include
UP
(active),
DN
(inactive).
lm0-7 (8-port)
lm0-15 (16-port)
The frame counts of active ports. The display shows the number
of frames transmitted and received and low level interface counts
(LLI_errs).
Central Memory
The central memory status. Possible values include
OK
,
FAULTY
.
Total diag frames Tx
The total diagnostics frames transmitted (Tx) since the last
startup. This number usually corresponds to the total frames
received (Rx) but may differ because of failure modes.
Total Diag Frames Rx
The total diagnostics frames received (Rx) since the last startup.
This number usually corresponds to the total frames transmitted
(Tx) but may differ because of failure modes.
portLoopbackTest
Figure 55 on page 109 shows the
portLoopbackTest
command, which verifies the
intended functional operation of the switch by sending frames from the transmitter
switch:admin> diagShow
Diagnostics Status:
Sun
Jan
1 00 : 00 : 00
2000
Port
number:
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
diags:
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
state:
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
lm0:
lm1:
lm2:
lm3:
lm4:
lm5:
lm6:
lm7:
lm8:
lm9:
lm10:
lm11:
lm12:
lm13:
lm14:
lm15:
39624101
39309877
39750791
39501243
40066092
40075160
39886034
39989371
40257892
39154671
39767848
40009605
39961890
39799377
40252478
40132745
frTx
frTx
frTx
frTx
frTx
frTx
frTx
frTx
frTx
frTx
frTx
frTx
frTx
frTx
frTx
frTx
40128685
40007305
39885106
40065867
39501463
40257190
39751716
39960595
40075855
40250787
39798346
39312144
39990666
39768879
39156315
39628100
frRx
frRx
frRx
frRx
frRx
frRx
frRx
frRx
frRx
frRx
frRx
frRx
frRx
frRx
frRx
frRx
Central Memory OK
Total Diag Frames Tx:
419264
Total Diag Frames Rx:
447200
Figure 54. diagShow command example
108