IBM 2109 Service Guide - Page 24

Loop (FL) connections, Offline tests are disruptive to switch operations. Do not run these tests

Page 24 highlights

v CMem data retention test (cmemRetentionTest) v CMI conn test (cmiTest) v Cross port test (crossPortTest) v Memory test (ramTest) v Port loopback test (portLoopbackTest) v Port register test (portRegTest) v Spin silk test (spinSilk) v SRAM data retention test (sramRetentionTest) v Switch offline (switchDisable) v Switch online (switchEnable) Table 5 shows the available offline and online tests. Attention: Offline tests are disruptive to switch operations. Do not run these tests unless you are sure that switch operation can be disrupted. Table 5. Offline and online test Offline tests Offline and online tests camTest centralMemoryTest crossPortTest ramTest cmemRetentionTest cmiTest portLoopbackTest portRegTest spinSilk sramRetentionTest Loop (FL) connections The system-board module is structured to accommodate a single channel FL_port interface module in the same slot used by the dual G_port interface module. Mixing | of FL_port and G_port interface modules in different slots is permitted. 8 IBM SAN Fibre Channel Switch: 2109 Model S16 Installation and Service Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178

v
CMem data retention test (cmemRetentionTest)
v
CMI conn test (cmiTest)
v
Cross port test (crossPortTest)
v
Memory test (ramTest)
v
Port loopback test (portLoopbackTest)
v
Port register test (portRegTest)
v
Spin silk test (spinSilk)
v
SRAM data retention test (sramRetentionTest)
v
Switch offline (switchDisable)
v
Switch online (switchEnable)
Table 5 shows the available offline and online tests.
Attention:
Offline tests are disruptive to switch operations. Do not run these tests
unless you are sure that switch operation can be disrupted.
Table 5. Offline and online test
Offline tests
Offline and online tests
camTest
crossPortTest
centralMemoryTest
ramTest
cmemRetentionTest
cmiTest
portLoopbackTest
portRegTest
spinSilk
sramRetentionTest
Loop (FL) connections
The system-board module is structured to accommodate a single channel FL_port
interface module in the same slot used by the dual G_port interface module. Mixing
of FL_port and G_port interface modules in different slots is permitted.
8
IBM SAN Fibre Channel Switch: 2109 Model S16 Installation and Service Guide
|