IBM 2109 Service Guide - Page 138
Diagnostic error messages
UPC - 087944519355
View all IBM 2109 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 138 highlights
| Table 40. Action codes and recommended actions (continued) | Action Recommended action | code | 4 Replace the power supply. See "Replacing the power supply" on page 45. | | | Diagnostic error messages | This section provides information on the probable cause of a diagnostic error and | what actions to take. | Table 41. Diagnostic error messages | Message Failing test | DIAG-BADINT | Err#1030 | Err#2030 centralMemoryTest cmiTest | DIAG| BUS_TIMEOUT | Err#0B0F | Err#4040F portRegTest sramRetentionTest | DIAG-CAMINIT | Err#223B || ||| | | CamTest | | | DIAG-CAMSID | Err#223C camTest | DIAG-CLEAR_ERR | Err#0001 | DIAG-CMBISRF | Err#1021 | centralMemoryTest | DIAG-CMBISRTO | Err#1020 | centralMemoryTest | DIAG-CMERRPTN centralMemoryTest | Err#102B | DIAG-CMERRTYPE centralMemoryTest | Err#102A | DIAG-CMICKSUM cmiTest | Err#2036 | DIAG-CMIDATA | Err#2035 cmiTest | DIAG-CMIINVCAP cmiTest | Err#2034 | DIAG-CMINOCAP | Err#2033 cmiTest Description The port received an interrupt when not expecting one. Probable cause ASIC failure Action 1 The ASIC register or ASIC SRAM ASIC failure 1 did not respond to an ASIC data access. The port failed to initialize due to one of the following reasons: v Switch is not disabled v Diagnostic queue absent v Malloc failed v Chip is not present v Port is not in loopback mode v Port is not active Software operational setup error or main boad failure Retry, restart or replace the mainboard assembly The ASIC failed SID NO ASIC failure 1 translation test. The port's diag error flag (OK or Informational only BAD) is cleared. None required The central memory SRAMs of ASIC failure 1 the ASIC did not complete the BISR within the timeout period. The central memory SRAMs of ASIC failure 1 the ASIC did not complete the BISR within the timeout period. An error was detected at the wrong port. ASIC failure The port got the wrong CMEM ASIC failure 1 error type. The CMI message received failed ASIC or system board 1 the bad checksum test. failure The CMI data received did not match the data transmitted. ASIC or system board 1 failure An unintended ASIC erroneously ASIC or system board 1 got CMI capture flag. failure The CMI intended receiver ASIC ASIC or system board 1 failed to get the CMI capture flag. failure 122 IBM SAN Fibre Channel Switch: 2109 Model S16 Installation and Service Guide