IBM 2109 Service Guide - Page 139
Message, Failing test, Description, Probable cause, Action, Enc_in, CRC_err, TruncFrm, FrmTooLong
UPC - 087944519355
View all IBM 2109 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 139 highlights
| Table 41. Diagnostic error messages (continued) | Message Failing test Description Probable cause Action | DIAG-CMISA1 | Err#2032 | cmiTest An attempt to send a CMI ASIC failure 1 message from ASIC to ASIC failed. | DIAG-CMNOBUF centralMemoryTest The port could not get any buffer. ASIC failure 1 | Err#1029 | DIAG-DATA | Err#266E | Err#306E portLoopbackTest crossPortTest The payload received by the port System board, GBIC 2 did not match the payload module, or fiber cable transmitted. failure | DIAG-ERRSTAT | Err#2640-2647 | Err#3040-3047 | Err#3840-3847 | | | | | | | | | | | | | | | portLoopbackTest crossPortTest spinSilk The port error statistics counter is ASIC, system board, 2 non-zero, meaning an error was GBIC module, or fiber detected when receiving frames. cable failure One of the following status errors occurred: v Enc_in - Encoding error, inside frame v CRC_err - Cyclic redundancy check on frame failed v TruncFrm - Truncated frame v FrmTooLong - Frame too long v BadEOF - Bad end of file v Enc_out - Encoding error, outside frame v BadOrdSet - Bad symbol on fiber-optic cable v DiscC3 - Discarded class 3 frames | DIAG-INIT | Err#264F | Err#304F | Err#384F portLoopbackTest crossPortTest spinSilk The port failed to go active in the ASIC, system board, 2 loopback mode requested. GBIC module, or fiber cable failure | DIAG-INTNIL | Err#2031 cmiTest ASIC failed to get a CMI error ASIC failure 1 (interrupt). | DIAG-INTNOTCLR centralMemoryTest The interrupt bit could not be ASIC failure 1 | Err#102C cleared. | DIAG-LCMEM centralMemoryTest Data read from the central ASIC failure 1 | Err#1027 cmemRetentionTest memory location did not match | data previously written into the | same location. | DIAG-LCMEMTX | Err#1F27 | Err#1028 centralMemoryTest A central memory transmit path System board failure 1 failure: ASIC 1 failed to read ASIC 2 using the transmit path. | DIAG-LCMRS centralMemoryTest A central memory read short: M ASIC failure 1 | Err#1F25 cmemRetentionTest bytes requested but got less than | Err#1025 M bytes. | DIAG-LCMTO centralMemoryTest A central memory timeout: Data ASIC failure 1 | Err#1F26 cmemRetentionTest transfer initiated did not complete | Err#1026 within the timeout period. | DIAG-MEMNULL | Err#0112 ramTest Test failed to malloc. System board failure 1 Appendix C. Error messages 123