IBM 2109 Service Guide - Page 61

Replacing FRUs, Parts catalog, Replacing the power supply

Page 61 highlights

Chapter 5. Replacing FRUs This chapter includes: v A parts catalog listing the part numbers for all field replaceable units (FRUs) v The FRU replacement process v The switch repair verification process Parts catalog Table 18 lists the field replaceable units (FRUs) available for the 2109 Model S16 Switch. Table 18. Field replaceable units (FRUs) list Description Part number Replace procedure reference Power supply 09L5418 See "Replacing the power supply" on page 45. GBIC module LW 03K9208 See "Replacing a GBIC module" on page 47. GBIC module SW 03K9206 See "Replacing a GBIC module" on page 47. Fan tray assembly 09L5438 See "Replacing a fan assembly" on page 48. System board 09L5440 See "Replacing the system board assembly" on page 49. Chassis assembly 09L5441 See "Replacing the chassis with touchpad" on page 50. 5 m fibre-channel cable 03K9202 25 m fibre-channel cable 03K9204 Rack slides 34L2722 See "Rack-mount installation" on page 20. Rack-mounting brackets 34L2767 See "Rack-mount installation" on page 20. Switch securing ears 34L2723 See "Rack-mount installation" on page 20. Replacing the power supply Before replacing the power supply, read the following Danger and Caution notices. DANGER To prevent a possible electrical shock during an electrical storm, do not connect or disconnect cables or station protectors for communications lines, display stations, printers, or telephones. (72XXD003) DANGER To prevent a possible electrical shock when adding or removing any devices to or from the system, ensure that the power cords for those devices are unplugged before the signal cables are connected or disconnected. If possible, disconnect all power cords from the existing system before you add or remove a device. (72XXD203) DANGER Do not attempt to open the covers of the power supply. Power supplies are not serviceable and are replaced as a unit. (72XXD300) © Copyright IBM Corp. 1999, 2000 45

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178

Chapter 5. Replacing FRUs
This chapter includes:
v
A parts catalog listing the part numbers for all field replaceable units (FRUs)
v
The FRU replacement process
v
The switch repair verification process
Parts catalog
Table 18 lists the field replaceable units (FRUs) available for the 2109 Model S16
Switch.
Table 18. Field replaceable units (FRUs) list
Description
Part number
Replace procedure reference
Power supply
09L5418
See “Replacing the power supply” on page 45.
GBIC module LW
03K9208
See “Replacing a GBIC module” on page 47.
GBIC module SW
03K9206
See “Replacing a GBIC module” on page 47.
Fan tray assembly
09L5438
See “Replacing a fan assembly” on page 48.
System board
09L5440
See “Replacing the system board assembly” on page 49.
Chassis assembly
09L5441
See “Replacing the chassis with touchpad” on page 50.
5 m fibre-channel cable
03K9202
25 m fibre-channel cable
03K9204
Rack slides
34L2722
See “Rack-mount installation” on page 20.
Rack-mounting brackets
34L2767
See “Rack-mount installation” on page 20.
Switch securing ears
34L2723
See “Rack-mount installation” on page 20.
Replacing the power supply
Before replacing the power supply, read the following Danger and Caution notices.
DANGER
To prevent a possible electrical shock during an electrical storm, do not
connect or disconnect cables or station protectors for communications
lines, display stations, printers, or telephones. (72XXD003)
DANGER
To prevent a possible electrical shock when adding or removing any
devices to or from the system, ensure that the power cords for those
devices are unplugged before the signal cables are connected or
disconnected. If possible, disconnect all power cords from the existing
system before you add or remove a device. (72XXD203)
DANGER
Do not attempt to open the covers of the power supply. Power supplies are
not serviceable and are replaced as a unit. (72XXD300)
© Copyright IBM Corp. 1999, 2000
45