IBM 2109 Service Guide - Page 77
fwShow command, command displays the thresholds monitored by Fabric Watch.
UPC - 087944519355
View all IBM 2109 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 77 highlights
| fwShow command | The fwShow command displays the thresholds monitored by Fabric Watch. || Synopsis fwShow | Availability All users | Description Use to display the thresholds monitored by Fabric Watch. If no parameters | are entered, a summary of all thresholds is displayed and printed. If a | valid threshold name is entered as a parameter, detailed information | pertaining only to that threshold is displayed and printed. | Operands None | Example Example of displaying the thresholds monitored by Fabric Watch: | sw:root> fwShow | | Name Label Last Value | | envTemp001 Env Temperature 1 33 C | envTemp002 Env Temperature 2 33 C | envTemp003 Env Temperature 3 36 C | envTemp004 Env Temperature 4 35 C | envTemp005 Env Temperature 5 36 C | envFan001 Env Fan 1 5070 RPM | envFan002 Env Fan 2 3090 RPM | envFan003 Env Fan 3 3150 RPM | envFan004 Env Fan 4 5130 RPM | envPS002 Env Power Supply 2 0 (1 OK/0 FAULT | sw:admin> fwShow "envTemp001" | Env Temperature 1: | Monitored for: 1283 (21 mins) | Last checked: 10:50:21 on 02/01/2000 | Lower bound: 0 C | Upper bound: 75 C | Buffer Size: 10 | Value history: 33 C | Disabled? No | Locked? No | See also fwClassInit | fwConfigReload | fwConfigure | | Chapter 6. Optional features 61