IBM 2109 Service Guide - Page 77

fwShow command, command displays the thresholds monitored by Fabric Watch.

Page 77 highlights

| fwShow command | The fwShow command displays the thresholds monitored by Fabric Watch. || Synopsis fwShow | Availability All users | Description Use to display the thresholds monitored by Fabric Watch. If no parameters | are entered, a summary of all thresholds is displayed and printed. If a | valid threshold name is entered as a parameter, detailed information | pertaining only to that threshold is displayed and printed. | Operands None | Example Example of displaying the thresholds monitored by Fabric Watch: | sw:root> fwShow | | Name Label Last Value | | envTemp001 Env Temperature 1 33 C | envTemp002 Env Temperature 2 33 C | envTemp003 Env Temperature 3 36 C | envTemp004 Env Temperature 4 35 C | envTemp005 Env Temperature 5 36 C | envFan001 Env Fan 1 5070 RPM | envFan002 Env Fan 2 3090 RPM | envFan003 Env Fan 3 3150 RPM | envFan004 Env Fan 4 5130 RPM | envPS002 Env Power Supply 2 0 (1 OK/0 FAULT | sw:admin> fwShow "envTemp001" | Env Temperature 1: | Monitored for: 1283 (21 mins) | Last checked: 10:50:21 on 02/01/2000 | Lower bound: 0 C | Upper bound: 75 C | Buffer Size: 10 | Value history: 33 C | Disabled? No | Locked? No | See also fwClassInit | fwConfigReload | fwConfigure | | Chapter 6. Optional features 61

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178

fwShow command
The
fwShow
command displays the thresholds monitored by Fabric Watch.
Synopsis
fwShow
Availability
All users
Description
Use to display the thresholds monitored by Fabric Watch. If no parameters
are entered, a summary of all thresholds is displayed and printed. If a
valid threshold name is entered as a parameter, detailed information
pertaining only to that threshold is displayed and printed.
Operands
None
Example
Example of displaying the thresholds monitored by Fabric Watch:
sw:root> fwShow
===========================================================
Name Label Last Value
---------------- ------------------------ ---------------
envTemp001 Env Temperature 1 33 C
envTemp002 Env Temperature 2 33 C
envTemp003 Env Temperature 3 36 C
envTemp004 Env Temperature 4 35 C
envTemp005 Env Temperature 5 36 C
envFan001 Env Fan 1 5070 RPM
envFan002 Env Fan 2 3090 RPM
envFan003 Env Fan 3 3150 RPM
envFan004 Env Fan 4 5130 RPM
envPS002 Env Power Supply 2 0 (1 OK/0 FAULT
sw:admin> fwShow "envTemp001"
Env Temperature 1:
Monitored for: 1283 (21 mins)
Last checked: 10:50:21 on 02/01/2000
Lower bound: 0 C
Upper bound: 75 C
Buffer Size: 10
Value history: 33 C
Disabled? No
Locked? No
See also
fwClassInit
fwConfigReload
fwConfigure
Chapter 6. Optional features
61
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|