Beep/symptom
![]() |
UPC - 087944734307
View all IBM 8671 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 141 highlights
Note: See "System" on page 162 to determine which components should be replaced by a field service technician. Beep/symptom FRU/action 3-1-1 (Timer tick interrupt failed) v System board 3-1-2 (Interval timer channel 2 failed) v System board 3-1-3 (RAM test failed above address OFFFFH)) 1. DIMM 2. System board 3-1-4 (Time-Of-Day clock failed) 1. Battery 2. System board 3-2-1 (Serial port failed) v System board 3-2-2 (Parallel port failed) v System board 3-2-3 (Math coprocessor test failed) 1. Microprocessor 2. System board 3-2-4 (Failure comparing CMOS memory size against actual) 1. DIMM 2. Battery 3-3-1 (Memory size mismatch occurred.) 1. DIMM 2. Battery 3-3-2 (Critical SMBUS error occurred) 1. Disconnect the server power cord from outlet, wait 30 seconds and retry. 2. System board. 3. DIMMs. 4. DASD backplane. 5. Power supply. 6. Power cage assembly, if installed. 7. 12C Cable. 3-3-3 (No operational memory in system) 1. Install or reseat the memory modules, and then do a 3 boot reset. (For more information on a 3 boot reset, see "Using the Configuration/Setup Utility program" on page 15.) 2. DIMMs. 3. Memory board. 4. System board. 4-4-4 (Optional system management 1. Verify that the adapter is installed in slot 1. adapter not installed in slot 1 or not functioning correctly) 2. Adapter. 3. System board. Two short beeps (Information only, the configuration has changed) 1. Run Diagnostics. 2. Run the Configuration/Setup Utility program. Three short beeps 1. DIMM 2. System board Chapter 6. Symptom-to-FRU index 131
![](/manual_guide/products/ibm-8671-hardware-maintenance-manual-61e0001/141.png)