IBM 8671 Hardware Maintenance Manual - Page 164
error, messages, Power
UPC - 087944734307
View all IBM 8671 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 164 highlights
Note: See "System" on page 162 to determine which components should be replaced by a field service technician. Message Action DASD under recommended temperature (sensor x) (level-warning; direct access storage device bay x had under temperature condition) v Ambient temperature must be within normal operating specifications; see "Features and specifications" on page 3. DASD Over Temperature (level-critical; sensor for DASD1 reported temperature over recommended range) v Ensure system is being properly cooled; see "System reliability considerations" on page 45. Power supply x Temperature Fault (level-critical; power supply x had over temperature condition) 1. Ensure system is being properly cooled; see "System reliability considerations" on page 45. 2. Replace power supply x System board is over recommended temperature (level-warning; system board is over recommended temperature) 1. Ensure system is being properly cooled; see "System reliability considerations" on page 45. 2. Replace the system board. System board is under recommended temperature (level-warning; system board is under recommended temperature) v Ambient temperature must be within normal operating specifications; see "Features and specifications" on page 3. System over temperature for CPU x (level-warning; CPU x reporting over temperature condition) v Ensure system is being properly cooled; see"System reliability considerations" on page 45. System under recommended CPU x temperature (level-warning; system reporting under temperature condition for CPU x) v Ambient temperature must be within normal operating specifications; see "Features and specifications" on page 3. Fan error messages Note: See "System" on page 162 to determine which components should be replaced by a field service technician. Message Action Fan x failure (level-critical; fan x had a failure) 1. Check connections to fan x. 2. Replace fan x. Fan x fault (level-critical; fan x beyond recommended RPM range) 1. Check connections to fan x. 2. Replace fan x. Fan x outside recommended speed action 1. Replace fan x. Power error messages Note: See "System" on page 162 to determine which components should be replaced by a field service technician. Message Action Power supply x current share fault (level-critical; excessive current demand on power supply x) v Replace power supply x. 154 xSeries 235 Type 8671: Hardware Maintenance Manual and Troubleshooting Guide