solved.
UPC - 883436005760
View all IBM x3500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 90 highlights
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the Problem Determination and Service Guide on the IBM System x Documentation CD to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Error code Description Action I9990305 An operating system was not found. 1. Make sure that a bootable operating system is installed. 2. Run the hard disk drive diagnostic tests. 3. Reseat the following components: a. Hard disk drive b. SAS hard disk drive backplane and cables c. DVD drive and cables 4. Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive b. SAS hard disk drive backplane and cables c. DVD drive and cables d. (Trained service technician only) System board I9990650 AC power has been restored. 1. Check the power cables. 2. Check for interruption of the power supply (see the Problem Determination and Service Guide on the IBM System x Documentation CD for information on the power-supply LEDs). 3. Reseat the following components: a. Power supply b. (Trained service technician only) Power backplane 4. Replace the components listed in step 3, one at a time, in the order shown, restarting the server each time. 76 IBM System x3500 Type 7977: Installation Guide