Intermec PC43d PC23 and PC43 Desktop Printer User Manual - Page 133
Clean the Platen Roller
View all Intermec PC43d manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 133 highlights
Chapter 6 - Maintain the Printer Warning: Do not touch the printhead surface area. 6 Connect the ribbon cable to the new printhead. 7 Slide the printhead into the holders in the print mechanism. 8 Press the printhead onto the locator pins in the mechanism. 9 Tilt the printhead up into the printer lid and press it into place. When the printhead is in the correct position, the printhead latches snap into place on the sides of the printhead. 10 For a thermal transfer printer, install the ribbon. 11 Close the printer lid until it snaps shut. 12 Print a test label. Clean the Platen Roller Follow this procedure to remove, clean, and replace the platen roller as part of standard maintenance for the printer. Intermec recommends that you check the platen roller for debris and clean it each time you replace media. 1 Turn the printer off and disconnect the power cord. 2 Pull one or both of the printer latches toward the front of the printer and lift the printer lid. 3 Remove the installed media. PC23 and PC43 Desktop Printer User Manual 119