Intermec PD41 PD41 and PD42 Commercial Printer User's Manual - Page 100
To run the LSS Auto test, Press Testfeed
View all Intermec PD41 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 100 highlights
Chapter 4 - Troubleshooting and Maintaining the Printer 3 Check the point of detection from the front with the printhead lifted. Point of detection If you are having detection problems, you can test the label stop sensor in Setup mode on the PD42. The label stop sensor tests can determine whether the sensor is in the right position, if it is blocked by dust or stuck labels, or if it is defective in some way. Setup mode has these two test functions: • LSS Auto: Checks to make sure that the label stop sensor is working properly and can detect gaps, slots, and black marks. • LSS Manual: Shows the sensor setting established by the latest Testfeed. LSS Manual is intended to be used by Intermec service personnel only. To run the LSS Auto test 1 Make sure the printer is correctly configured for the type of media you are using. 2 Press Testfeed ( ). Test 86 PD41 and PD42 Commercial Printer User's Manual