Kyocera KM-C2230 Fiery X3e 22C-KM Configuration Guide for KM-C2230 - Page 172

Troubleshooting, After this Setup screen, This message, Means, Setup>PServer Setup>NDS

Page 172 highlights

AA-2 Troubleshooting After this Setup screen Frame Type selection (Network Setup>Protocol Setup>IPX/SPX Setup) Enable NDS (Network Setup>Service Setup>PServer Setup >NDS Setup) Select NDS Tree (Network Setup>Service Setup >PServer Setup> NDS Setup) Navigating NDS tree (Network Setup>Service Setup > PServer Setup > NDS Setup) Bindery Setup (Network Setup>Service Setup >PServer Setup > Bindery Setup) This message Invalid frame size. Warning! IPX network number is zero. No NDS trees found. Warning! Selecting a new NDS tree deletes Bindery setup. ___ is empty. Means The network hub is not connected to a Novell server when the Fiery X3e tries to bind. No other IPX server can be found on the network, or the network hub is not connected to the network when the Fiery X3e tries to bind. When this occurs, the network number defaults to zero. No NDS trees were found on the Novell network. Check to see that the frame types on the Fiery X3e are properly configured. You have previously connected the Fiery X3e to a different NDS tree. NetWise supports only a single NDS tree connection. To avoid a potential conflict with an existing tree connection (for example, if the connection was made through a NetWare 4.x server in emulation mode), all bindery settings will be deleted. If you choose OK (copier) or Set (printer), and choose Yes in the following message (Delete Bindery setup and continue?), bindery settings are deleted and have to be reentered in Bindery Setup. To avoid deleting the bindery settings, press the Menu key, or select OK (copier) or Set (printer) and choose No in the following message (Delete Bindery setup and continue?). Repeat NDS Setup without changing the NDS tree, or exit to Bindery Setup to review your current bindery settings. The chosen container contains no sub-containers or objects relevant to the current mode of navigation. If you also plan to use NDS, set up NDS before Bindery. No NDS settings are present. You are reminded to perform NDS Setup before Bindery Setup in case your network includes both NDS and bindery servers.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190

A
A-2
Troubleshooting
Frame Type selection
(Network Setup>Protocol
Setup>IPX/SPX Setup)
Enable NDS
(Network Setup>Service
Setup>PServer Setup>NDS
Setup)
Invalid frame size.
The network hub is not connected to a Novell server when
the Fiery X3e tries to bind.
Warning! IPX network
number is zero.
No other IPX server can be found on the network, or the
network hub is not connected to the network when the
Fiery X3e tries to bind. When this occurs, the network
number defaults to zero.
No NDS trees found.
No NDS trees were found on the Novell network. Check
to see that the frame types on the Fiery X3e are
properly
configured.
Select NDS Tree
(Network Setup>Service
Setup>PServer Setup>
NDS Setup)
Warning! Selecting a new
NDS tree deletes Bindery
setup.
You have previously connected the Fiery X3e to a different
NDS tree. NetWise supports only a single NDS tree
connection. To avoid a potential conflict with an existing
tree connection (for example, if the connection was made
through a NetWare 4.x server in emulation mode), all
bindery settings will be deleted.
If you choose OK (copier) or Set (printer), and choose Yes
in the following message (Delete Bindery setup and
continue?), bindery settings are deleted and have to be re-
entered in Bindery Setup.
To avoid deleting the bindery settings, press the Menu key,
or select OK (copier) or Set (printer) and choose No in the
following message (Delete Bindery setup and continue?).
Repeat NDS Setup without changing the NDS tree, or exit
to Bindery Setup to review your current bindery settings.
Navigating NDS tree
(Network Setup>Service
Setup > PServer Setup >
NDS Setup)
___ is empty.
The chosen container contains no sub-containers or objects
relevant to the current mode of navigation.
Bindery Setup
(Network Setup>Service
Setup>PServer Setup>
Bindery Setup)
If you also plan to use NDS,
set up NDS before Bindery.
No NDS settings are present. You are reminded to perform
NDS Setup before Bindery Setup in case your network
includes both NDS and bindery servers.
After this Setup screen
This message
Means