Lantronix XPort XChip - User Guide - Page 59

Setup Mode: Advanced Settings, Email Settings (Option 3), DeviceInstaller

Page 59 highlights

8. Setup Mode: Advanced Settings Email Settings (Option 3) Note: You can change these settings using Telnet, a serial connection, or Web Manager with firmware versions 6.1.0.0 or later. Earlier versions do not allow you to configure email triggers using Web Manager. To configure email settings using DeviceInstaller, see Email Notification in the DeviceInstaller Online Help. The unit sends an email to multiple recipients when a specific trigger event occurs. There are three separate triggers, based on any combination of the configurable pins (PIO) when selected as user I/O functions. Optionally, use a two-byte serial string to initiate a trigger. To configure email configuration settings, select Email (option 3) from the Change Setup menu. Figure 8-1. Email Settings *** E-mail Mail server: 0.0.0.0 Unit : Domain : Recipient 1: Recipient 2: - Trigger 1 Serial trigger input: disabled Channel: 1 Match: 00 Trigger input1: X Trigger input2: X Trigger input3: X Message : Priority: L Min. notification interval: 1 s Re-notification interval : 0 s - Trigger 2 Serial trigger input: disabled Channel: 1 Match: 00 Trigger input1: X Trigger input2: X Trigger input3: X Message : Priority: L Min. notification interval: 1 s Re-notification interval : 0 s - Trigger 3 Serial trigger input: disabled Channel: 2 Match: 00 XPort User Guide 59

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87

8. Setup Mode: Advanced Settings
Email Settings (Option 3)
Note:
You can change these settings using Telnet, a serial connection, or Web
Manager with firmware versions 6.1.0.0 or later. Earlier versions do not allow you to
configure email triggers using Web Manager. To configure email settings using
DeviceInstaller, see Email Notification in the DeviceInstaller Online Help.
The unit sends an email to multiple recipients when a specific trigger event occurs.
There are three separate triggers, based on any combination of the configurable pins
(PIO) when selected as user I/O functions. Optionally, use a two-byte serial string to
initiate a trigger.
To configure email configuration settings, select
Email
(option
3
) from the Change
Setup menu.
Figure 8-1. Email Settings
*** E-mail
Mail server: 0.0.0.0
Unit
:
Domain
:
Recipient 1:
Recipient 2:
- Trigger 1
Serial trigger input: disabled
Channel: 1
Match: 00
Trigger input1: X
Trigger input2: X
Trigger input3: X
Message :
Priority: L
Min. notification interval: 1 s
Re-notification interval
: 0 s
- Trigger 2
Serial trigger input: disabled
Channel: 1
Match: 00
Trigger input1: X
Trigger input2: X
Trigger input3: X
Message :
Priority: L
Min. notification interval: 1 s
Re-notification interval
: 0 s
- Trigger 3
Serial trigger input: disabled
Channel: 2
Match: 00