Lantronix XPort XChip - User Guide - Page 73
Command 19h, Set Directions, Command 1Ah, Set Active Levels, Command 1Bh, Set States
View all Lantronix XPort manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 73 highlights
9: GPIO Interface Command 19h, Set Directions Send: 2 parameters Bytes 1-4: Mask Bit X 1 means the direction for GPIO X will be updated with the value in the second parameter. 0 means the direction for that GPIO will not change. Bytes 5-8: New Directions Bit X 1 means GPIO X will become an output. 0 means it will become an input. Response: 1 parameter Bytes 1-4: The updated directions Command 1Ah, Set Active Levels Send: 2 parameters Bytes 1-4: Mask Bit X 1 means the direction for GPIO X will be updated with the value in the second parameter. 0 means the active type for that GPIO will not change. Bytes 5-8: New Active Levels Bit X 1 means GPIO X will become active low. 0 means it will become active high. Response: 1 parameter Bytes 1-4: Updated active levels Command 1Bh, Set States Send: 2 parameters Bytes 1-4: Mask Bit X 1 means the state for GPIO X will be updated with the value in the second parameter. 0 means the state for that GPIO will not change. Bytes 5-8: New States Bit X 1 means GPIO X will become active. 0 means it will become inactive. Response: 1 parameter Bytes 1-4: Updated states XPort User Guide 73