Lantronix XPort XChip - User Guide - Page 61

Trigger 2, Expert Settings (Option 5)

Page 61 highlights

8: Setup Mode: Advanced Settings Set the configurable pins to A = Active, I = Inactive, or X = Don't Care. Active can mean active low or active high. If the configurable pins are all set to b (Don't Care), then they are disabled. If both the serial sequence and the configurable pins are disabled, the trigger is disabled. To change the configurable pins' settings, send setup records to Port 77FE. Message The subject line of the trigger event email to the specified recipient(s). Priority The priority level for the trigger even email. Enter L for normal priority or H for high priority. Minimum notification interval The minimum time allowed between individual triggers. If a trigger event occurs within the minimum interval since the last trigger, it is ignored. Re-notification interval Indicates the time interval at which a new email message is sent to the recipient(s) when a single trigger event remains active. Trigger 2 Refer to Trigger 1 for details on completing these fields. Note: Each trigger is independent of the others. Each condition within an individual trigger must be met before the unit sends the email. Trigger 3 Refer to Trigger 1 for details on completing these fields. Note: Each trigger is independent of the others. Each condition within an individual trigger must be met before the unit sends the email. Expert Settings (Option 5) Note: You can change the Enable alternate MAC setting using telnet or serial connections only. It is not available through the Web Manager. CAUTION: Only an expert should change these parameters. You must definitely know the consequences the changes might have. Figure 8-2. Expert Settings TCP Keepalive time in s (1s - 65s; 0s=disable): (45) ? ARP Cache timeout in s (1s - 600s) : (600) ? CPU performance (0=Regular, 1=Low, 2=High): (0) ? Disable Monitor Mode @ bootup (N) ? RS485 tx enable active level (0=low; 1=high): (0) ? HTTP Port Number : (80) ? SMTP Port Number : (25) ? MTU Size (512 - 1400): (1400) ? TCP Re-transmission Timeout (500 - 4000) (ms): (500) ? Enable alternate MAC (N) ? Ethernet connection type: (0) ? XPort User Guide 61

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87

8: Setup Mode: Advanced Settings
Set the configurable pins to
A
= Active,
I
= Inactive, or
X
= Don’t Care. Active can
mean active low or active high. If the configurable pins are all set to b (Don’t Care),
then they are disabled. If both the serial sequence and the configurable pins are
disabled, the trigger is disabled.
To change the configurable pins’ settings, send setup records to Port 77FE.
Message
The subject line of the trigger event email to the specified
recipient(s).
Priority
The priority level for the trigger even email. Enter L for normal
priority or H for high priority.
Minimum notification
interval
The minimum time allowed between individual triggers. If a trigger
event occurs within the minimum interval since the last trigger, it is
ignored.
Re-notification interval
Indicates the time interval at which a new email message is sent to
the recipient(s) when a single trigger event remains active.
Trigger 2
Refer to
Trigger 1
for details on completing these fields.
Note:
Each trigger is independent of the others. Each condition within an individual
trigger must be met before the unit sends the email.
Trigger 3
Refer to
Trigger 1
for details on completing these fields.
Note:
Each trigger is independent of the others. Each condition within an individual
trigger must be met before the unit sends the email.
Expert Settings (Option 5)
Note:
You can change the Enable alternate MAC setting using telnet or serial
connections only. It is not available through the Web Manager.
CAUTION:
Only an expert should change these parameters. You must
definitely know the consequences the changes might have.
Figure 8-2. Expert Settings
TCP Keepalive time in s (1s - 65s; 0s=disable):
(45) ?
ARP Cache timeout in s (1s - 600s) :
(600) ?
CPU performance (0=Regular, 1=Low, 2=High):
(0) ?
Disable Monitor Mode @ bootup (N) ?
RS485 tx enable active level (0=low; 1=high):
(0) ?
HTTP Port Number :
(80) ?
SMTP Port Number :
(25) ?
MTU Size (512 - 1400):
(1400) ?
TCP Re-transmission Timeout (500 - 4000) (ms):
(500) ?
Enable alternate MAC (N) ?
Ethernet connection type:
(0) ?
XPort User Guide