Lantronix XPort XChip - User Guide - Page 65

SNMP Community Name, Disable Telnet Setup, Disable TFTP Firmware Upgrade, Disable Port 77FE (Hex), - tool

Page 65 highlights

8: Setup Mode: Advanced Settings SNMP Community Name The SNMP Community Name is a required field for NMS to read or write to a device. Enter a string of 1 to 13 characters. SNMP Community Name (public): _ The default entry is public. The current value is displayed in parentheses. Disable Telnet Setup Note: If you choose to disable this option, keep in mind that disabling both Telnet Setup and Port 77FE will prevent users from accessing the setup menu from the network. This setting defaults to the N (No) option. The Y (Yes) option disables access to Setup Mode by Telnet (port 9999). It only allows access locally using the web pages and the serial port of the unit. Disable Telnet Setup (N) ? _ Disable TFTP Firmware Upgrade This setting defaults to the N (No) option. The Y (Yes) option disables the use of TFTP to perform network firmware upgrades. With this option, you can download firmware upgrades over the serial port using DeviceInstaller's Recover Firmware procedure. (See 10 Firmware Upgrades.) Disable TFTP Firmware Update (N) : _ Disable Port 77FE (Hex) Note: If you choose to disable this option, keep in mind that disabling both Telnet Setup and Port 77FE will prevent users from accessing the setup menu from the network. Port 77FE is a setting that allows DeviceInstaller, Web Manager, and custom programs to configure the unit remotely. You may wish to disable this capability for security purposes. Disable Port 77FEh (N) ? _ The default setting is the N (No) option, which enables remote configuration. You can configure the unit by using DeviceInstaller, web pages, Telnet, or serial configuration. The Y (Yes) option disables remote configuration and web sites. Note: The Y (Yes) option disables many of the GUI tools for configuring the unit, including the embedded Web Manager tool. Disable Web Server This setting defaults to the N (option). The Y (Yes) option disables the web server. Disable Web Server (N) ? _ XPort User Guide 65

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87

8: Setup Mode: Advanced Settings
SNMP Community Name
The SNMP Community Name is a required field for NMS to read or write to a device.
Enter a string of 1 to 13 characters.
SNMP Community Name (public): _
The default entry is
public
. The current value is displayed in parentheses.
Disable Telnet Setup
Note:
If you choose to disable this option, keep in mind that disabling both Telnet
Setup and Port 77FE will prevent users from accessing the setup menu from the
network.
This setting defaults to the
N
(No) option. The
Y
(Yes) option disables access to
Setup Mode by Telnet (port 9999). It only allows access locally using the web pages
and the serial port of the unit.
Disable Telnet Setup (N) ? _
Disable TFTP Firmware Upgrade
This setting defaults to the
N
(No) option. The
Y
(Yes) option disables the use of
TFTP to perform network firmware upgrades. With this option, you can download
firmware upgrades over the serial port using DeviceInstaller’s Recover Firmware
procedure. (See
10 Firmware Upgrades
.)
Disable TFTP Firmware Update (N) : _
Disable Port 77FE (Hex)
Note:
If you choose to disable this option, keep in mind that disabling both Telnet
Setup and Port 77FE will prevent users from accessing the setup menu from the
network.
Port 77FE is a setting that allows DeviceInstaller, Web Manager, and custom
programs to configure the unit remotely. You may wish to disable this capability for
security purposes.
Disable Port 77FEh (N) ? _
The default setting is the
N
(No) option, which enables remote configuration. You can
configure the unit by using DeviceInstaller, web pages, Telnet, or serial configuration.
The
Y
(Yes) option disables remote configuration and web sites.
Note:
The
Y
(Yes) option disables many of the GUI tools for configuring the unit,
including the embedded Web Manager tool.
Disable Web Server
This setting defaults to the
N
(option). The
Y
(Yes) option disables the web server.
Disable Web Server (N) ? _
XPort User Guide
65