NEC NP-M300X M260W : user's manual - Page 37

Checking Energy-Saving Effect [CARBON METER]

Page 37 highlights

3. Convenient Features NOTE: • The [ECO MODE] can be changed by using the menu. Select [SETUP] → [GENERAL] → [ECO MODE]. • The lamp life remaining and lamp hours used can be checked in [USAGE TIME]. Select [INFO.] →[USAGE TIME]. • The projector is always in [ECO1]* for 90 seconds after the lamp is turned on and while the POWER indicator is blinking green. The lamp condition will not be affected even when [ECO MODE] is changed. • After a lapse of 1 minute from when the projector displays no-signal guidance, a blue, black or logo screen, [ECO MODE] will automatically switch to [ECO1]*. The projector will return to the [OFF] once a signal is accepted. • If the projector is overheated in [OFF] mode, there may be a case where the [ECO MODE] automatically changes to [ECO1]* mode to protect the projector. When the projector is in [ECO1]* mode, the picture brightness decreases. When the projector comes back to normal temperature, the [ECO MODE] returns to [OFF] mode. Thermometer symbol [ ] indicates the [ECO MODE] is automatically set to [ECO1]* mode because the internal temperature is too high. * [ECO2] on M300X and M260X only Checking Energy-Saving Effect [CARBON METER] This feature will show energy-saving effect in terms of CO2 emission reduction (kg) when the projector's [ECO MODE] is set to [AUTO ECO], [ECO1], or [ECO2]. This feature is called as [CARBON METER]. There are two messages: [TOTAL CARBON SAVINGS] and [CARBON SAVINGS-SESSION]. The [TOTAL CARBON SAVINGS] message shows the total amount of CO2 emission reduction from the time of shipment up to now. You can check the information on [USAGE TIME] from [INFO.] of the menu. (→ page 88) The [CARBON SAVINGS-SESSION] message shows the amount of CO2 emission reduction between the time of changing to ECO MODE immediately after the time of power-on and the time of power-off. The [CARBON SAVINGSSESSION] message will be displayed in the [POWER OFF/ ARE YOU SURE?] message at the time of power-off. TIP: • The formula as shown below is used to calculate the amount of CO2 emission reduction. Amount of CO2 emission reduction = (Power consumption in OFF for ECO MODE − Power consumption in AUTO ECO/ECO1/ECO2 for ECO MODE) × CO2 conversion factor.* When the image is turned off with the AV MUTE button or with the lens cover closed, the amount of CO2 emmission reduction will also increase. * Calculation for amount of CO2 emission reduction is based on an OECD publication "CO2 Emissions from Fuel Combustion, 2008 Edition". • The [TOTAL CARBON SAVINGS] is calculated based on savings recorded in 15 minutes intervals. • This formula will not apply to the power consumption which is not affected by whether [ECO MODE] is turned on or off. 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136

27
3. Convenient Features
NOTE:
• The [ECO MODE] can be changed by using the menu.
Select [SETUP]
[GENERAL]
[ECO MODE].
• The lamp life remaining and lamp hours used can be checked in [USAGE TIME]. Select [INFO.]
[USAGE TIME].
• The projector is always in [ECO1]* for 90 seconds after the lamp is turned on and while the POWER indicator is blinking green.
The lamp condition will not be affected even when [ECO MODE] is changed.
• After a lapse of 1 minute from when the projector displays no-signal guidance, a blue, black or logo screen, [ECO MODE] will
automatically switch to [ECO1]*. The projector will return to the [OFF] once a signal is accepted.
• If the projector is overheated in [OFF] mode, there may be a case where the [ECO MODE] automatically changes to [ECO1]* mode
to protect the projector. When the projector is in [ECO1]* mode, the picture brightness decreases. When the projector comes
back to normal temperature, the [ECO MODE] returns to [OFF] mode.
Thermometer symbol [
] indicates the [ECO MODE] is automatically set to [ECO1]* mode because the internal temperature is
too high.
* [ECO2] on M300X and M260X only
Checking Energy-Saving Effect [CARBON METER]
This feature will show energy-saving effect in terms of CO
2
emission reduction (kg) when the projector’s [ECO MODE]
is set to [AUTO ECO], [ECO1], or [ECO2].This feature is called as [CARBON METER].
There are two messages:[TOTAL CARBON SAVINGS] and [CARBON SAVINGS-SESSION].The [TOTAL CARBON
SAVINGS] message shows the total amount of CO
2
emission reduction from the time of shipment up to now.You can
check the information on [USAGE TIME] from [INFO.] of the menu. (
page
88
)
The [CARBON SAVINGS-SESSION] message shows the amount of CO
2
emission reduction between the time of
changing to ECO MODE immediately after the time of power-on and the time of power-off.The [CARBON SAVINGS-
SESSION] message will be displayed in the [POWER OFF/ AREYOU SURE?] message at the time of power-off.
TIP:
• The formula as shown below is used to calculate the amount of CO
2
emission reduction.
Amount of CO
2
emission reduction = (Power consumption in OFF for ECO MODE − Power consumption in AUTO ECO/ECO1/ECO2
for ECO MODE) × CO
2
conversion factor.* When the image is turned off with the AV MUTE button or with the lens cover closed,
the amount of CO
2
emmission reduction will also increase.
* Calculation for amount of CO
2
emission reduction is based on an OECD publication “CO
2
Emissions from Fuel Combustion, 2008
Edition”.
• The [TOTAL CARBON SAVINGS] is calculated based on savings recorded in 15 minutes intervals.
• This formula will not apply to the power consumption which is not affected by whether [ECO MODE] is turned on or off.