Tripp Lite PDU3VSR6L2130 Owner's Manual for SNMPWEBCARD 9332CE - Page 29

Identification

Page 29 highlights

4. Telnet/SSH Console continued 4.1 Device Menu continued 4.1.2 Identification This is the section of the device menus that will contain the information about the device. This information will be both user-defined settings such as device name or location and equipment specific information like vendor, product and protocol. There are data items on this menu which will be displayed for all devices and some data displayed based upon the type and protocol for the device. Any data that is modifiable by the user will have a prompt option displayed on the menu. Device Identification Menu -------- Identification Device Name : Device 1 Location : Region : Vendor : TRIPPLITE Product : SMART750RM1U Protocol : 3003 Date Installed : 2011-07-31 State : CRITICAL Type : UPS Port Mode : RS232 Port Name : /com/1 VA Rating : 750 VA Firmware Version : 2264 (Rev A) Input Line Count : 1 Load Banks Total : 3 Load Banks Controllable : 2 Serial Number : Device ID : 1280 1- Name 2- Location 3- Region 4- Date Installed 5- Serial Number 6- Device ID X- Device Main Menu M- Return to Main Menu Refresh Menu Menu Data The following is the data that should be displayed for all devices. Device Name This is the user modifiable device name. The system will give the device a default name. The default for a UPS or PDU is "Device X" where X is the device ID number. The default for an ENVIROSENSE is "Probe." The default for SRCOOLNET is "AC." Location The user-defined device location. There is no default for location. Region The user-defined device region. There is no default for region. State This is the current alarm state of the device. The valid values are: • NORMAL • INFORMATION • WARNING • STATUS • CRITICAL • OFFLINE Vendor This is the manufacturer of the device. Product This is the device model. Protocol This is the protocol used by the device. Type This is the device type. The valid values are: • UPS • PDU • ENVIROSENSE • AC Date Installed This is the date that the device was installed. For a UPS, this will be used for the battery installed date and is therefore modifiable. 29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100

29
4. Telnet/SSH Console
continued
4.1 Device Menu
continued
4.1.2 Identification
This is the section of the device menus that will contain the information about the device. This information will be both user-defined settings such
as device name or location and equipment specific information like vendor, product and protocol. There are data items on this menu which will be
displayed for all devices and some data displayed based upon the type and protocol for the device. Any data that is modifiable by the user will have
a prompt option displayed on the menu.
Device Identification Menu
-------- Identification --------------------------------------------------------
Device Name
: Device 1
Location
:
Region
:
Vendor
: TRIPPLITE
Product
: SMART750RM1U
Protocol
: 3003
Date Installed
: 2011-07-31
State
: CRITICAL
Type
: UPS
Port Mode
: RS232
Port Name
: /com/1
VA Rating
: 750 VA
Firmware Version
: 2264 (Rev A)
Input Line Count
: 1
Load Banks Total
: 3
Load Banks Controllable
: 2
Serial Number
:
Device ID
: 1280
1- Name
2- Location
3- Region
4- Date Installed
5- Serial Number
6- Device ID
X- Device Main Menu
M- Return to Main Menu
<ENTER> Refresh Menu
Menu Data
The following is the data that should be displayed for all devices.
Device Name
This is the user modifiable device name. The system will give the device
a default name. The default for a UPS or PDU is “Device X” where X is
the device ID number. The default for an ENVIROSENSE is “Probe.” The
default for SRCOOLNET is “AC.”
Location
The user-defined device location. There is no default for location.
Region
The user-defined device region. There is no default for region.
Vendor
This is the manufacturer of the device.
Product
This is the device model.
Protocol
This is the protocol used by the device.
Date Installed
This is the date that the device was installed. For a UPS, this will be used
for the battery installed date and is therefore modifiable.
State
This is the current alarm state of the device. The valid values are:
NORMAL
INFORMATION
WARNING
STATUS
CRITICAL
OFFLINE
Type
This is the device type. The valid values are:
UPS
PDU
ENVIROSENSE
AC