Tripp Lite PDU3VSR6L2130 Owner's Manual for SNMPWEBCARD 9332CE - Page 35

Load Configuration

Page 35 highlights

4. Telnet/SSH Console continued 4.1 Device Menu continued 4.1.5 Loads To access the load menus, the user must have at least Read access to the DEVICE LOADS and DEVICE STATUS facilities. Additionally, a user may be able to update Loads options by accessing outlet realms. You can control the outlets of a managed device by selecting the load plugged into it and clicking the desired [On], [Off] or [Cycle] control. Each load bank consists of one or more outlets. You can use the "Description" field to label the banks for easy reference. The main control buttons affect all outlets at once. Warning! The load controls start or stop the flow of electricity to your device's outlets. Make sure you know what equipment is connected to each load bank before attempting to use these controls! Check the outlet labels and/or test the load banks by plugging a circuit tester or small light into each outlet and observing the effects of the controls. 4.1.5.1 Load Configuration Menu Data Edit Description Use this menu to enter custom labels for load banks. This can be used to help identify equipment quickly and easily before using the controls to cycle the bank ON or OFF. Change Realm Assigning a realm to an individual outlet or group of outlets creates a logical grouping that can be used to assign user access. Turn Load On/Off This menu controls the state of the outlet. Cycle Load This command can be used to turn the load OFF and back ON in a single command. Change Ramp Action Select if the outlet should stay OFF or turn ON when ramp actions are triggered. Change Ramp Delay If setting the ramp action to turn ON, this command sets the delay before the action occurs. Change Shed Action Select if the outlet should stay ON or turn OFF when shed actions are triggered. Change Shed Delay If setting the shed action to turn OFF, this command sets the delay before the action to occur. Load Group: Ramp Settings Action: Delay: Turn On After Delay 2 Shed Settings Action: Delay: Turn Off After Delay 3 1- Edit Description 2- Change Realm 3- Turn Load Off 4- Cycle Load 5- Change Ramp Action 6- Change Ramp Delay 7- Change Shed Action 8- Change Shed Delay X- Load Menu M- Return to Main Menu Refresh Menu >> x Loads Menu 35

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100

35
4. Telnet/SSH Console
continued
4.1 Device Menu
continued
4.1.5 Loads
To access the load menus, the user must have at least Read access to the DEVICE LOADS and DEVICE STATUS facilities. Additionally, a user may
be able to update Loads options by accessing outlet realms.
You can control the outlets of a managed device by selecting the load plugged into it and clicking the desired [On], [Off] or [Cycle] control. Each
load bank consists of one or more outlets.
You can use the “Description” field to label the banks for easy reference. The main control buttons affect all outlets at once.
Warning! The load controls start or stop the flow of electricity to your device’s outlets. Make sure you know what equipment is
connected to each load bank before attempting to use these controls! Check the outlet labels and/or test the load banks by plugging
a circuit tester or small light into each outlet and observing the effects of the controls.
4.1.5.1 Load Configuration
Menu Data
Edit Description
Use this menu to enter custom labels for load banks. This can be used
to help identify equipment quickly and easily before using the controls
to cycle the bank ON or OFF.
Change Realm
Assigning a realm to an individual outlet or group of outlets creates a
logical grouping that can be used to assign user access.
Turn Load On/Off
This menu controls the state of the outlet.
Cycle Load
This command can be used to turn the load OFF and back ON in a
single command.
Load Group:
Ramp Settings
Action:
Turn On After Delay
Delay:
2
Shed Settings
Action:
Turn Off After Delay
Delay:
3
1- Edit Description
2- Change Realm
3- Turn Load Off
4- Cycle Load
5- Change Ramp Action
6- Change Ramp Delay
7- Change Shed Action
8- Change Shed Delay
X- Load Menu
M- Return to Main Menu
<ENTER> Refresh Menu
>> x
-------------Loads Menu ---------------------
Change Ramp Action
Select if the outlet should stay OFF or turn ON when ramp actions are
triggered.
Change Ramp Delay
If setting the ramp action to turn ON, this command sets the delay
before the action occurs.
Change Shed Action
Select if the outlet should stay ON or turn OFF when shed actions are
triggered.
Change Shed Delay
If setting the shed action to turn OFF, this command sets the delay
before the action to occur.